STATTOO: A New Product For Tattoo and Piercing Professionals

Almost one in every four Americans has a tattoo,

according to a 2006 study conducted by the Journal of the American Academy of Dermatology.

However, this common procedure poses the risk of serious disease transmission to both the artist and their customers. Possible infections as a result of inadequately sterilized reusable equipment range from Staphylococcus Aureus, (including a potentially deadly, drug-resistant type of staph infection that has been reported among unlicensed tattoo artists in at least three states), to Hepatitis C and HIV.

Infection control areas in tattoo studios where reusable equipment is sterilized are often in nonvisible rooms as discussion surrounding infection control, and the equipment they use can often be seen to be as intimidating to customers.

STATTOO sterilizes in only 6 minutes - right in your booth
STATTOO sterilizes in only 6 minutes – right in your booth

SciCan, the world leader in tabletop autoclaves has developed a tattoo-specific machine that will not only optimize the sterility of reusable equipment, but will put infection control front and center – namely, right front of the customer.

Smaller, lighter and more portable than a traditional device, the ‘STATTOO’ is designed to be located right in the procedure area so customers can see the sterilization process and ensure they are receiving freshly sterilized instruments.

In addition, the ‘STATTOO’ can sterilize 10x faster (6 mins vs. 60 mins) than conventional devices – which is fast enough to sterilize between procedures – an industry first. This unprecedented speed greatly reduces instrument bottlenecks and provides tattoo professionals opportunity to increase the number of procedures possible due to the speed in which instruments can be introduced back into the workflow.

With an exterior design by tattoo artist Scott McEwan, ‘STATTOO is an extremely unique product offering for a community that continues to face more complex infection control challenges’ says Andrew Zwingenberger, National Sales Manager for SciCan Medical USA ‘with a look that compliments its surroundings.’

STATIM is designed to exceed those infection control challenges faced by the body art professional’. He continues, ‘quite frankly, this product will not only provide tattoo artists a distinct performance advantage, but we see this as an opportunity to show off their sterilization process – front and center – and generate dialogue about infection control with their customers’.

The STATIM 900 autoclave is currently not in production, but may return as a G4 version in the future.

VistaPure Replacement Filter Pack

R3250
$567
In stock
1
Product Details
Brand: SciCan
Model: Statim, StatClave, Bravo, Hydrim C, Hydrim L

Filters for your Steri-Center’s best friend.

VistaPure™ provides two grades of high-quality water for autoclaves, dental bottles, ultrasonic cleaners and instrument washers for the ultimate convenience.


VistaPure filter replacement schedule details

It is not typically necessary to change all the filters at the same time. The pre-filter and polishing filter should be changed at least once per year and the deionization and hyper filtration filters changed only as needed as indicated by TDS tests.
Here are some basic guidelines: pre-filter and polishing filter elements should be changed annually in relatively rare instances of source water with unusually high levels of sediment or debris such as areas surrounded by heavy construction. The pre filter element may need to be changed more frequently due to premature plugging of the filter.
The ionization filters typically last anywhere from four months to three years depending on the volume of usage and the quality of the local water supply. Both the ionization filters should be changed whenever the system mounted TDS meter in the "out" position displays a number equal to or greater than four parts per million. It's important never to fill an autoclave with water with greater than five parts per million TDS.
VistaPure's hyper filtration element typically only needs to be replaced every three to five years depending on the volume of usage and the quality and pressure of the local water supply. Replace the hyper filtration element whenever the system mounted TDS meter in the "in" position exceeds 10% of the TDS of the municipal water supply feeding the system as measured with the included handheld meter checking water quality with the provided TDS meters monthly will help you keep ahead of required filter changes.
Please note that water should be running through the system when checking water quality using the system mounted TDS meter, simply run the Vista peer faucet for a few moments in the system will start to produce water and yield accurate results. Also please note that all filters are not created equal using inferior knockoff filter elements or following protocols different from those specified by the manufacturer may result in less than desirable outcomes and inhibits our ability to provide customer service and warranty support for the system.

How to Change VistaPure Filters

The Prefilter & Polishing filter should be changed at least once per year, and the Deionization and Hyperfiltration filters only need to be changed on an as-needed basis.