Chamber Autoclave
The Perfect Blend of Speed and Capacity
The BRAVO fractionated vacuum chamber autoclave continues the SciCan tradition of being at the forefront of innovation and technology. BRAVO is true to the STATIM reputation for speed, providing rapid cycles for all types of instrument loads. BRAVO is a class B fractionated vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post sterilization vacuum to improve drying.

Speed
The BRAVO is one of the fastest chamber autoclaves on the market today.
- Incorporating both pre-vac (to remove air) and post-vac (to help drying) phases, Bravo technology ensures perfect steam penetration and rapid cycles for all instrument loads.
- BRAVO offers the perfect blend of speed and capacity; total cycle times, including drying, are completed in about half the time of other chamber autoclaves.
- BRAVO 17V and 21V are two of the fastest chamber autoclaves on the market, sterilizing and drying instruments in as little as 24-28 minutes.

Dry
With closed door drying and vacuum technology, the BRAVO is able to dry faster than other chamber autoclaves.
- BRAVO’s DriTec Vacuum heat drying gives fast and consistent loads every time.
- Intelligent drying cycle options detect when moisture is removed from instruments and packaging, tailoring the drying time to each load.
- DriTec technology heats the chamber while a vacuum removes and evaporates any remaining moisture on the instruments.

Versatile
Bravo offers numerous sterilization cycles and filling & draining options, making it the ideal sterilizer for every practice.
- With 12 different cycle options, including a Vacuum and Bowie Dick test cycle, Bravo ensures you are using the appropriate parameters for every instrument load.
- The single use water system ensures fresh water is used with every load.
- Front, top and rear mounted water and filling ports make the Bravo ideal for every Steri-center set-up.
- Utilizing an easily accessible USB port, the Bravo allows cycle data to be stored digitally, making record keeping simple and efficient.
Bravo 17V with cassettes Bravo 21V with cassettes and packages

BRAVO Sterilization Cycle Specifications
Cycles (134°C for 4 minutes) | Cycle Times (including drying**) | Max Weight |
BRAVO 17V | ||
---|---|---|
Porous/wrapped | 35 | • |
Hollow/unwrapped | 27 | 6kg/13.6lbs |
Solid/wrapped | 24 | 3kg/6.6lbs |
Solid/unwrapped | 19 | 6kg/13.6lbs |
BRAVO 21V | ||
Porous/wrapped | 40 | • |
Hollow/unwrapped | 32 | 7.5kg/16.5lbs |
Solid/wrapped | 28 | 4.0kg/8.8lbs |
Solid/unwrapped | 23 | 7.5kg/16.5lbs |
**Note: Cycle times represent 220V models. * 17(V)/ 21V: Unpackaged porous materials:1kg/1.25kg, Porous material in single package: 0.75kg / 1.0kg, Solid material/hollow instruments in single pack: 3kg/4kg, Solid material/hollow instruments in double package:1.5kg / 2.0kg.
BRAVO Technical Specifications
BRAVO 17V | |
---|---|
Size L × W × H*** | 22.0 × 19.0 × 16.5″ 560 × 480 × 420mm |
Volume | 4.5 gal/17L |
Dimension | D10 × L13.5″ D254 × L343mm |
Weight | 128lbs /55kg |
Voltage | 120V, 15A or 220V, 10A |
BRAVO 21V | |
Size L × W × H*** | 25.0 × 19.0 × 16.5″ 635 × 480 × 420mm |
Volume | 5.5 gal/ 21L |
Dimension | D10 × L17.5” D254 × L445mm |
Weight | 139lbs /63kg |
Voltage | 120V, 15A or 220V, 10A |
*** When installed into cabinets, a minimum 4”/2” (102mm / 51mm) free cool air space is required on the back/sides, and top of the unit.
Download
Brochure
Manual

BRAVO
Bravo vacuum autoclaves