STATTOO: A New Product For Tattoo and Piercing Professionals

Almost one in every four Americans has a tattoo,

according to a 2006 study conducted by the Journal of the American Academy of Dermatology.

However, this common procedure poses the risk of serious disease transmission to both the artist and their customers. Possible infections as a result of inadequately sterilized reusable equipment range from Staphylococcus Aureus, (including a potentially deadly, drug-resistant type of staph infection that has been reported among unlicensed tattoo artists in at least three states), to Hepatitis C and HIV.

Infection control areas in tattoo studios where reusable equipment is sterilized are often in nonvisible rooms as discussion surrounding infection control, and the equipment they use can often be seen to be as intimidating to customers.

STATTOO sterilizes in only 6 minutes - right in your booth
STATTOO sterilizes in only 6 minutes – right in your booth

SciCan, the world leader in tabletop autoclaves has developed a tattoo-specific machine that will not only optimize the sterility of reusable equipment, but will put infection control front and center – namely, right front of the customer.

Smaller, lighter and more portable than a traditional device, the ‘STATTOO’ is designed to be located right in the procedure area so customers can see the sterilization process and ensure they are receiving freshly sterilized instruments.

In addition, the ‘STATTOO’ can sterilize 10x faster (6 mins vs. 60 mins) than conventional devices – which is fast enough to sterilize between procedures – an industry first. This unprecedented speed greatly reduces instrument bottlenecks and provides tattoo professionals opportunity to increase the number of procedures possible due to the speed in which instruments can be introduced back into the workflow.

With an exterior design by tattoo artist Scott McEwan, ‘STATTOO is an extremely unique product offering for a community that continues to face more complex infection control challenges’ says Andrew Zwingenberger, National Sales Manager for SciCan Medical USA ‘with a look that compliments its surroundings.’

STATIM is designed to exceed those infection control challenges faced by the body art professional’. He continues, ‘quite frankly, this product will not only provide tattoo artists a distinct performance advantage, but we see this as an opportunity to show off their sterilization process – front and center – and generate dialogue about infection control with their customers’.

The STATIM 900 autoclave is currently not in production, but may return as a G4 version in the future.

StatClave G4

G4-621103
$9,150
STATCLAVE G4 is a Class B vacuum sterilizer with an 11 inch chamber as a companion to your STATIM for loads of packages
In stock
1
Product Details
Brand: SciCan
Model: StatClave G4

*(120V) Wifi enabled, waste water direct to drain included


This changes everything. Again.

Introducing the STATCLAVE™ Chamber Autoclave


With the reliability and trust you’ve come to expect from STATIM, the STATCLAVE G4 is designed to deliver speed, capacity and efficiency to your practice. STATCLAVE is a Class B vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilized and dried wrapped instruments.


Fast

STAT*CLAVE* G4

STATCLAVE can efficiently sterilize and dry wrapped instrument loads in as little as 38 minutes.

Dry

Closed-door drying and vacuum technology results in perfectly dried instruments every time.

G4 Technology

SciCan’s G4 equipment can connect and send information to your smart devices or computer so you can have cycle data, instructions, and maintenance notifications at your fingertips.

Capacity

STATCLAVE’s 11” chamber can sterilize up to four full-size cassettes and 4 exam cassettes or 20 pouches with included pouch racks.

Versatile

STATCLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.

Gentle

Fresh water is used in every cycle, reducing the buildup of oils and debris.


STATCLAVE G4 Chamber Autoclave

Featuring the STATCLAVE G4 Chamber Autoclave for sterilizing dental instruments.


STATCLAVE G4 Launch at PDC 2019

Ted Gray and Melissa Summerfield discuss the latest innovation from SciCan, the STATCLAVE G4 Chamber Autoclave.



STATCLAVE G4 In-Service

An overview of installing, operating, and maintaining the SciCan STATCLAVE G4 Chamber Autoclave.

Cycle Times and Maximum Load Weights (120v)

Cycles
Temperature / Time
Cycle Times*
Maximum Load Weight
STATCLAVE G4
Solid Unwrapped
270°F (132°C) / 4 mins
18 mins
13.2 lbs (6 kg)
Solid Wrapped
270°F (132°C) / 4 mins
44 mins
13.2 lbs (6 kg)
Hollow Unwrapped
270°F (132°C) / 4 mins
23 mins
13.2 lbs (6 kg)
Hollow Wrapped
270°F (132°C) / 4 mins
50 mins
13.2 lbs (6 kg)
Textiles/Porous
270°F (132°C) / 4 mins
49 mins
4.4 lbs (2 kg)
Rubber & Plastic
250°F (121°C) / 20 mins
36 mins
4.4 lbs (2 kg)

*Cycle time will vary depending on instrument load.



Unit Specifications

STATCLAVE G4
Unit size (L x W x H)†
25” x 17.75" x 19.5" / 635 x 450 x 495mm
Volume
6.87 gal (26 L)
Chamber Dimensions (D x L)
11" diameter, 15" depth / 297 x 381mm
Weight
61.6 kg (135.8 lbs) (without water and packaging)
Voltage
120V, 60Hz, 12 A

†On the right side, allow 2” (50mm) of space for ventilation. Allow for at least 7” (180mm) above unit to enable access to reservoirs. If less than 7” (180mm), screw on hinges can be removed to allow reservoir lid to slide in and out of position.


Download

Brochure

STATCLAVE G4

Operator Manual

STATCLAVE G4 Quick Reference Guide



Save up to 35% off the list price of a StatClave autoclave when you use your Section 179 tax deduction: Click here for more info

Save this product for later

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.