STATTOO: A New Product For Tattoo and Piercing Professionals

Almost one in every four Americans has a tattoo,

according to a 2006 study conducted by the Journal of the American Academy of Dermatology.

However, this common procedure poses the risk of serious disease transmission to both the artist and their customers. Possible infections as a result of inadequately sterilized reusable equipment range from Staphylococcus Aureus, (including a potentially deadly, drug-resistant type of staph infection that has been reported among unlicensed tattoo artists in at least three states), to Hepatitis C and HIV.

Infection control areas in tattoo studios where reusable equipment is sterilized are often in nonvisible rooms as discussion surrounding infection control, and the equipment they use can often be seen to be as intimidating to customers.

STATTOO sterilizes in only 6 minutes - right in your booth
STATTOO sterilizes in only 6 minutes – right in your booth

SciCan, the world leader in tabletop autoclaves has developed a tattoo-specific machine that will not only optimize the sterility of reusable equipment, but will put infection control front and center – namely, right front of the customer.

Smaller, lighter and more portable than a traditional device, the ‘STATTOO’ is designed to be located right in the procedure area so customers can see the sterilization process and ensure they are receiving freshly sterilized instruments.

In addition, the ‘STATTOO’ can sterilize 10x faster (6 mins vs. 60 mins) than conventional devices – which is fast enough to sterilize between procedures – an industry first. This unprecedented speed greatly reduces instrument bottlenecks and provides tattoo professionals opportunity to increase the number of procedures possible due to the speed in which instruments can be introduced back into the workflow.

With an exterior design by tattoo artist Scott McEwan, ‘STATTOO is an extremely unique product offering for a community that continues to face more complex infection control challenges’ says Andrew Zwingenberger, National Sales Manager for SciCan Medical USA ‘with a look that compliments its surroundings.’

STATIM is designed to exceed those infection control challenges faced by the body art professional’. He continues, ‘quite frankly, this product will not only provide tattoo artists a distinct performance advantage, but we see this as an opportunity to show off their sterilization process – front and center – and generate dialogue about infection control with their customers’.

The STATIM 900 autoclave is currently not in production, but may return as a G4 version in the future.

Lumen water distiller cleaner

6603
$38
In stock
1
Product Details
Brand: Pure Scientific

Lumen Water Distiller Cleaner and Descaler is used to remove mineral deposits in the boiling tank of your water distiller. It’s important to clean your water distiller’s boiling tank every month or after making 30 gallons of water. Regular maintenance improves the functioning and longevity of your Pure Scientific Water Distiller.

  • Improves heating element performance
  • Regular maintenance improves longevity of machine
  • Descales and removes mineral buildup
  • Maintains a clean appearance
  • Improves boiling tank appearance
  • May be used to descale other items like tea pots*

(*If item has electronic components please check manual before using)


*Will ship separately by FedEx ground.

NOTE: LUMEN CAN ONLY SHIP GROUND IN CONTINENTAL U.S. AND CANNOT BE RETURNED.

How To Clean Your Boiling Tank – Mini Classic Water Distiller

Cleaning the Boiling Chamber:

Sometimes scale will build up inside the boiling chamber. This needs to be removed periodically to ensure good heating element life, and high-quality water. NOTE: If you rinse the boiling chamber every time you fill it, it will help reduce the maintenance needed.

NOTE: If you live in a "soft water area," or you have a water softener, your unit may rarely need cleaning.

To Clean the Boiling Chamber:

1. Turn the power switch to the OFF position.

2. If the unit has been operating, allow it to cool for 30 minutes from the end of the distillation cycle.

3. Carefully remove the boiling chamber from the unit.
CAUTION: The boiling chamber will get hot and could cause a burn if the unit has not been allowed to cool.

4. Remove the boiling chamber lid (4).

5. Drain any residual water inside the boiling chamber (1).

6. Fill the boiling chamber to the water level indicator (2).

7. Add Lumen Cleaner (stock #6603) to the boiling chamber. Follow instructions on the label.

NOTE: DO NOT replace the boiling chamber back into the unit during the cleaning process. DO NOT allow the unit to operate with the Lumen Cleaner in the boiling chamber.

Lumen

Mix 2 tablespoons of the Lumen Cleaner formula with water and pour the solution into the boiling tank. Let the solution sit overnight. Next day, get rid of the residues, rinse off the boiling tank, clean it, fill it up with water up to the water level indicator, run the first batch, discard and then you are good to start producing distilled water.