From SARS to Swine Flu

Protecting Your Practice

As of April 29, 2009, human cases of Swine Flu have been confirmed in the USA, Mexico, Canada and six other countries worldwide and have been suspected in many other nations. Deaths have been reported in the US and Mexico.

OPTIM can help stop the Swine Flu epidemicThe World Health Organization warned that the swine flu outbreak is moving closer to becoming a pandemic, and raised its pandemic alert to phase 5 (phase 6 is the highest in the scale; it is for a full-scale pandemic).

Just how safe are we against the Swine Flu? According to the WHO, CDC and Health Canada, taking precautions to protect yourself and your practice is the best course of action.

Surface disinfection in dental and medical practices is performed daily. However, which product is the best choice?

Accelerated Hydrogen Peroxide technology in OPTIMOPTIM 33TB, with AHP (accelerated hydrogen peroxide) technology, is a surface cleaner and disinfectant that has gained the reputation as being one of the most effective and safe surface disinfectants on the market.

It has a 1 minute virucidal claim against both enveloped (easy to kill viruses such as Influenza) and nonenveloped viruses (difficult to kill viruses such as Polio) which provides an added level of “comfort and confidence” in the event of a viral outbreak.

Its superior virucidal efficacy was recognized and subsequently recommended for the cleaning and disinfection of surfaces within all major healthcare facilities in Ontario Canada during the widely publicized SARS epidemic in early 2003. AHP was chosen because of its unique ability to balance rapid effectiveness with user and patient safety.

Confidence is key in any outbreak situation and when dealing with a relatively unknown virus such as new strains of the H1N1 Swine Flu.

OPTIM contains no VOC’s (Volatile Organic Compounds) and carries no precautionary warnings on the label (EPA Cat. 4). OPTIM 33TB provides safer infection control for tattoo, piercing, dental and medical staff, their patients and their environment.

For more information about OPTIM 33TB and protecting yourself against the Swine Flu, in a Tattoo or Body Art Studio / Dental or Medical Practice contact us.

Alternatively, go to www.scican.com or contact SciCan directly.

In the U.S.A. 1.800.572.1211

In Canada 1.800.667.7733

To order OPTIM 33TB

Statim 2000 USED / REFURBISHED

2000SPECIAL
$3,760
Pre-order
1
Product Details
Brand: SciCan
Model: 2000 Classic

STATIM 2000 Cassette Autoclave


Reconditioned used units validated and spore tested with one year warranty

  • Ultra-fast 6 minute unwrapped cycle
  • 14 minute wrapped cycle
  • Exceptional instrument turnover
  • 10 minute Dri-Tecc Drying Technology
  • Aseptic transfer of instrument directly to the point-of-use
  • Reduced instrument investment
  • Prolongs instrument life

The STATIM 2000 Classic boasts a 6-minute cycle, but has the added advantage of employing a fully removable chamber so you can aseptically transport a set of freshly sterilized instruments directly to the procedure area.

The STATIM 2000 is fully automatic. Simply select one of the three sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's STATIM cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States, and Europe.

The STATIM 2000 is a reliable cassette sterilizer that's compact enough to fit in procedure areas and fast enough to sterilize jewelry, expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just six minutes and a wrapped cycle in 14 minutes.

Dri-TecC Convection Heat Drying for the STATIM 2000

Dri-TecC – Convection heat drying technology

The STATIM 2000 uses convection heat to dry instruments by utilizing the remaining heat in the system after the sterilization phase. Heat is captured and released into the cassette, drying wrapped instrument loads in as little as 10 minutes.

Sterilization cycle description chart

Cycle Unwrapped Wrapped Rubber/Plastic
Sterilization time 3.5 minutes 10 minutes 15 minutes
Sterilization temp. 135º C 135º C 121º C
Total cycle time 6 minutes 14 minutes 20 minutes

ACCESSORIES available in the Shop:

01-100008A Cassette complete (with rack 01-106653)
01-100028S Seal & lubricant kit
01-100207S Air compressor filter
01-102119S Microbiological air filter
01-100812S Waste bottle complete
01-100204S Exhaust tube
01-103945S Instrument rack for unwrapped instruments
01-106653 Instrument rack for wrapped instruments
SCI134 Test Strip indicators (box of 250)
01-101783S Water reservoir cap & filter
01-109300S Water reservoir filter

statim_2000_cassettesysTM_cassetteSurgical Plastic Sterilization TraysStat-Dri Plus

SPECIFICATIONS:

Unit Size : L 480mm x W 415mm x H 150mm
L 19" x W 16.25" x H 6"
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11" x W 7" x H 1.5"
Reservoir Capacity : 4.0 litres (distilled water) Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 1300 W

When you receive your Statim 2000 packing carton, the items listed below will be included.
If any of the items are missing, contact us immediately so that the situation can be corrected.

  • Cassette Tray and Lid
  • Unwrapped Instrument Rack
  • Waste Bottle
  • Bottle Lid Fitting
  • Power Cord
  • Operator's Manual
  • Exhaust Tube
  • Tube Mounting Hardware

Finance your equipment at our checkout

*The use of STATIM sterilizers was introduced to the body art field in the early 1990's by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

Save this product for later