Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Elevate Your Craft: Advanced Sterilization Training for Body Piercers

SKU seminar
Pay what you want
500 or more
$
Live training!
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Elevate Your Craft: Advanced Sterilization Training for Body Piercers
Product Details
Brand: Piercers.com

Intensive workshop

Unlock a more comprehensive knowledge of Sterilization for piercing with Brian Skellie.

Elevate Your Craft:

This seminar is designed for professional body piercers seeking to elevate their sterilization protocols and ensure the highest standards of hygiene for their clients.

Who Should Attend:


  • Professional body piercers
  • Studio owners and managers

Why Attend:


  • Gain in-depth knowledge of STATIM 2000 G4, BRAVO, and STATCLAVE autoclaves for efficient and effective instrument and jewelry sterilization.
  • Master the HYDRIM C61W washer for optimal cleaning before sterilization.
  • Learn best practices for maintaining a safe environment in your piercing studio.
  • Network with fellow professionals and share ideas and techniques.

Topics we can cover together:


  • STATIM 2000 G4: The Power of High-Speed Steam Sterilization:


    • Overview of STATIM 2000 G4 features and benefits
    • Demonstration of cycle selection and operation
    • Q&A session

  • BRAVO and STATCLAVE Autoclaves: Reliable Solutions for Larger Loads:


    • Understanding the functionalities of BRAVO and STATCLAVE autoclaves
    • Selecting the appropriate cycle for different instruments and jewelry
    • Maintenance and troubleshooting tips






  • HYDRIM C61W Washer: The Key to Pre-Sterilization Cleaning (45 minutes):


    • Importance of proper pre-cleaning before sterilization
    • Features and functions of the HYDRIM C61W washer
    • Demonstrating the cleaning process for instruments and jewelry
    • Selecting the right detergents and cycles

  • Maintaining a Safe Environment in Your Studio (45 minutes):


    • Best practices for aseptic technique
    • Storage and handling of sterilized instruments and jewelry
    • Waste management and disposal procedures


  • Jewelry Materials science and style

Additional Information:


  • Attendees will receive a certificate of completion.




Registration Calendar: times and dates available

Resources:

Instructor:





  • Brian W Skellie: Renowned technician with extensive experience in maintaining sterilization equipment for body piercing and tattoo professionals. Brian is a body art specialist with a focus on aseptic piercing techniques. He is a long-time member of the Association of Professional Piercers and has been involved in the body art industry for over 30 years. Skellie founded Piercing Experience in 1992 and is an expert on infection prevention and sterilization. He is also an authorized dealer of COLTENE SciCan Statim autoclaves and Hydrim instrument washers, making him uniquely qualified to provide this training session.

By attending this seminar, body piercers can gain valuable knowledge and skills to ensure a safe and hygienic piercing experience for their clients.

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.