Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

StatClave G4

SKU G4-621103
$9,850
Cutting Edge Sterilization
List price $11,007.89 Save $1,157.89
STATCLAVE G4 is a Class B vacuum sterilizer with an 11 inch chamber as a companion to your STATIM for loads of packages
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
StatClave G4
Product Details
Brand: SciCan
Model: StatClave G4
Weight: 145 lbs

*(120V) Wifi enabled, waste water direct to drain included


This changes everything. Again.

Introducing the STATCLAVE™ Chamber Autoclave


With the reliability and trust you’ve come to expect from STATIM, the STATCLAVE G4 is designed to deliver speed, capacity and efficiency to your practice. STATCLAVE is a Class B vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilized and dried wrapped instruments.


Fast

STAT*CLAVE* G4

STATCLAVE can efficiently sterilize and dry wrapped instrument loads in as little as 38 minutes.

Dry

Closed-door drying and vacuum technology results in perfectly dried instruments every time.

G4 Technology

SciCan’s G4 equipment can connect and send information to your smart devices or computer so you can have cycle data, instructions, and maintenance notifications at your fingertips.

Capacity

STATCLAVE’s 11” chamber can sterilize up to four full-size cassettes and 4 exam cassettes or 20 pouches with included pouch racks.

Versatile

STATCLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.

Gentle

Fresh water is used in every cycle, reducing the buildup of oils and debris.


STATCLAVE G4 Chamber Autoclave

Featuring the STATCLAVE G4 Chamber Autoclave for sterilizing dental instruments.


STATCLAVE G4 Launch at PDC 2019

Ted Gray and Melissa Summerfield discuss the latest innovation from SciCan, the STATCLAVE G4 Chamber Autoclave.



STATCLAVE G4 In-Service

An overview of installing, operating, and maintaining the SciCan STATCLAVE G4 Chamber Autoclave.

Cycle Times and Maximum Load Weights (120v)

Cycles
Temperature / Time
Cycle Times*
Maximum Load Weight
STATCLAVE G4
Solid Unwrapped
270°F (132°C) / 4 mins
18 mins
13.2 lbs (6 kg)
Solid Wrapped
270°F (132°C) / 4 mins
44 mins
13.2 lbs (6 kg)
Hollow Unwrapped
270°F (132°C) / 4 mins
23 mins
13.2 lbs (6 kg)
Hollow Wrapped
270°F (132°C) / 4 mins
50 mins
13.2 lbs (6 kg)
Textiles/Porous
270°F (132°C) / 4 mins
49 mins
4.4 lbs (2 kg)
Rubber & Plastic
250°F (121°C) / 20 mins
36 mins
4.4 lbs (2 kg)

*Cycle time will vary depending on instrument load.



Unit Specifications

STATCLAVE G4
Unit size (L x W x H)†
25” x 17.75" x 19.5" / 635 x 450 x 495mm
Volume
6.87 gal (26 L)
Chamber Dimensions (D x L)
11" diameter, 15" depth / 297 x 381mm
Weight
61.6 kg (135.8 lbs) (without water and packaging)
Voltage
120V, 60Hz, 12 A

†On the right side, allow 2” (50mm) of space for ventilation. Allow for at least 7” (180mm) above unit to enable access to reservoirs. If less than 7” (180mm), screw on hinges can be removed to allow reservoir lid to slide in and out of position.


Download

Brochure

STATCLAVE G4

Operator Manual

STATCLAVE G4 Quick Reference Guide



Save up to 35% off the list price of a StatClave autoclave when you use your Section 179 tax deduction: Click here for more info



Edison Award winner: STATCLAVE G4 (SCICAN)

Inventors: The Business Development Team at SciCan Inc.

COMPLIANCE IS of the utmost importance in dentistry, and it just might be the buzzword of this year’s Edison nominees, too. Juggling the requirements of OSHA, the CDC and other governing bodies is no easy feat, and maintaining clean tools is a nonnegotiable first step.


“Generally, we found that offices are struggling to keep up with the throughput of instruments,” says Stacey Graf, product manager for SciCan, the Canonsburg, Pennsylvania–based infection-control company that debuted the Statim autoclave in the 1980s. “Nobody wants to stay late to sterilize instruments because they don’t have the right equipment for their workload.”

SciCan set out to produce a bigger, better, more modern version of the industry-altering Statim. The result is the StatClave G4, which received FDA approval this past autumn. “Industry leaders have been looking for a large sterilizer that was also fast and able to dry instruments effectively,” Graf says. “With the StatClave, we focused on having both: dryness and speed.”

The StatClave G4’s 11-inch chamber makes it one of the largest on the market. It can hold four 8-by-11-inch cassettes or about 20 pouches, and, using vacuum technology, takes just 38 minutes from start to finish—25 minutes less than similarly sized products. Plus, the pesky problem of still-moist tools after a sterilization cycle is eliminated. “We’re talking completely bone-dry,” Graf says.

The device is smart—that is, it can connect to the internet, too. Its G4 technology stores a memory of each sterilization cycle in the cloud that clinicians can log into the portal to see. (Another record-keeping win for compliance.) In the event of a system failure, SciCan will be sent a message and reach out to the office to help solve the problem. “The StatClave will help avoid bottlenecks in the sterilization process,” Graf says. “Patients aren’t waiting for clean tools, and staff can go home on time.” We’ll toast to that.