Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Bravo G4 Chamber Autoclave

SKU 7A620010
$8,495
The BRAVO G4 Chamber Autoclave is a Class B sterilizer that addresses a Piercing or Tattoo Studio’s need for speed, capacity, safety, and efficiency. A companion to your STATIM for loads of wrapped instruments and jewelry.
Model Size
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Bravo G4 Chamber Autoclave
Product Details
Brand: SciCan
Model: Bravo 21V
Weight: 139 lbs

The BRAVO G4 Chamber Autoclave is an EN13060 compliant Class B sterilizer that addresses a dental office’s need for speed, capacity, safety, and efficiency. Its cutting-edge sterilization technology incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying.

Efficient

  • The BRAVO G4 chamber autoclaves offer efficient cycle times, sterilizing and drying instruments in as little as 33 minutes.
  • The delayed start feature allows the user to program cycles to begin at a later time; an effective feature when programming test cycles to begin before the start of the day.

Versatile

  • Offering enough capacity to meet the needs of any size practice, the BRAVO G4 comes in 17L, 22L, or 28L chamber size.
  • The BRAVO G4 offers numerous filling and draining options, including manual top and front filling, and automatic filling and draining through ports at the back.
  • The accessory water equipment and the BRAVO G4 footprint allows options for any Stericentre set-up.

G4 Technology

Connectivity & Data Logging

  • Integrated G4 technology in the BRAVO G4 allows for reliable load release, documentation and data storage.
  • WiFi enabled G4 technology can connect and send cycle data to your smart devices or computer, providing easily accessible cycle data and maintenance information.
  • To help optimise office processes, the BRAVO G4 can be configured to email cycle information or error messages directly to office staff and/or service technicians.
Cycle 17L 22L 28L
Cycle Type Cycle Time (mins) Max. Load (kg) Cycle Time (mins) Max. Load (kg) Cycle Time (mins) Max. Load (kg)
134°C Universal B 42 6 46 7.5 56 9
134°C Hollow Unwrapped S 35 6 39 7.5 44 9
134°C Solid Wrapped S 33 6 39 7.5 45 9
134°C Prion B 56 6 60 7.5 70 9
121°C Universal B 58 6 63 7.5 69 9
134°C Helix Test N/A 20 N/A 24 N/A 24 N/A
Vacuum Test N/A 18 N/A 18 N/A 18 N/A
Custom (134°C or 121°C) N/A N/A N/A N/A N/A N/A N/A


BRAVO G4 Sterilization, The Smarter Way.

The BRAVO G4, a Type B sterilizer, incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. The option of 17L, 22L or 28L units and efficient turnover times ensure clinicians always have an ample supply of instruments ready for use, regardless of practice size

Download