Stat-Dri Plus

STAT-DRI Plus Drying / Rinse Agent For faster drying

For faster drying and seal lubrication coat the STATIM Cassette: After cleaning and drying the cassette, treat the interior surfaces with STAT-DRI Plus.
Add to the rinse aid dispenser on your HYDRIM instrument washer for effective drying results. Use StatDri Plus Drying agent for dramatically improved STATIM, BRAVO and HYDRIM drying and to extend the life of your STATIM seal.

You’ll notice the difference on your first cycle!

Stat-Dri Use Protocol

STATIM 2000/5000 Operator’s Manual 95-108027 Rev 5.0.
Copyright 2008 SciCan Ltd . All rights reserved.

3.9 Preparing Unit for Use

Once the unit is installed and before any instruments are sterilized, run two Wrapped Cycles (see Section 4.8 Statim 2000 – Running a Cycle and 4.10 Statim 5000 – Running a Cycle). Remove the cassette once it has cooled. Clean the top (lid) and bottom (tray) sections using a soft cloth to wipe the inside surfaces and then rinse thoroughly with tap water. Once the cassette is clean and dry, coat the inside surfaces with STAT-DRI.

STAT-DRI

Treatment of the interior surfaces of the cassette with the STAT-DRI drying agent, provided with your unit, will enhance the drying process. (Replacement bottles are available from SciCan, order number 2OZPLUS, 8OZPLUST, 32OZPLUS).

4.3 Statim 5000 — STAT-DRI Plates

The Statim 5000 cassette uses STAT-DRI plates to enhance the drying process for wrapped instruments. The adjustable plates are designed for the unwrapped instruments rack and eliminate the need for a separate wrapped instrument rack. Up to ten plates can be arranged along the length of the rack. Each unit is shipped with five STAT-DRI plates. Additional plates may be ordered from SciCan (SciCan part number 01-103935).

To install and adjust a STAT-DRI plate, follow these steps:

  1. Hold a plate over the desired position, tilted slightly forward with the tabs down.
  2. Insert the tabs between the mesh of the unwrapped instrument rack.
  3. Each tab has an elongated slot. Slide the plate until the wire is at the end of each slot.
  4. Release the plate to the resting position.
  5. Prepare and load instruments for sterilization.

5.1 Cleaning the Cassette

Keeping the Statim cassette clean is good clinical practice and assists in the function of the unit. SciCan recommends that the interior surface be cleaned at least once a week. Use dishwashing soap or a mild detergent that does not contain chlorine. Scrub the inside of the cassette with a cleaning pad designed for use with Teflon™ coated surfaces. After scouring, rinse thoroughly with water to remove all traces of the detergent. Cleaning the inside of your cassette is very important if you regularly sterilize lubricated instruments. Coating the entire inside surface with STAT-DRI / STAT-DRI PLUS drying agent induces water to form an even coat on the inside surface, without beading. The water in contact with the hot cassette surfaces also evaporates much more efficiently. Spotting is minimized and instruments dry much better. STAT-DRI / STAT-DRI PLUS should be applied every 10 cycles, and after every cassette cleaning.



Stat-Dri vs. Jet-Dry

Stat-Dri Plus is specially formulated to protect stainless steel instruments. All microbiological sterilization efficacy testing has been done using Stat-Dri. We have not conducted such tests using Jet-Dry, and therefore cannot provide any data to support using any Jet-Dry products as an alternative.

Keep in mind there are several flavours of Jet-Dry on the market, including Jet-Dry with baking soda, Jet-Dry Turbo-Dry, etc. all of which have slightly different chemical composition. As a result, customers who choose to use Jet-Dry instead of Stat-Dri do so at their ‘own risk’.

Courtesy of Statim.us

 

Statim 2000 G4

G4-121101
$6,490
Latest revision STATIM 2000 G4 for Piercers with new touchscreen, PC board, and probe bracket with recessed thermocouple
In stock
1
Product Details
Brand: SciCan
Model: 2000 G4

Fast, Gentle, Reliable, and Smart.

Introducing The New Generation of Statim, The Statim G4 Series

(Generation Four)

Download brochure

Canonsburg, PA – SciCan has set the benchmark for sterilization and instrument reprocessing technology.

For more than 25 years SciCan has been developing and manufacturing highly innovative infection control products that address the need for versatility, flexibility, and efficiency in today’s environments.

SciCan is proud to unveil the newest STATIM family member, the G4 series. The STATIM G4 series is the same renowned and trusted autoclave it has been for over 25 years but now boasts a new contemporary look, functionality and connectivity that is the first of its kind. The G4 technology will change the way you interact by providing a direct channel of communication through the Internet to increase productivity and limit downtime.

Still powered by SciCan’s signature steam technology to provide sterilization at speeds faster than conventional chambered autoclaves, the STATIM G4 series has been drastically upgraded with a level of interactivity not seen before.

New look

The STATIM G4 series has been modernized with a new fascia that is fresh and contemporary.

Color touch screen

A large 3.5” high-resolution touchscreen offers a vivid display of messages and current cycle information all with extraordinary clarity. The bubble level has been integrated into the high-resolution touchscreen.

Built-in data logger

Gone are the days of messy thermal paper, clumsy printers or potential failures with external data loggers. With increasing stringency amongst national guidelines, the STATIM G4 series now saves all the data from each cycle. This data can be copied onto the included USB drive, viewed on screen, or remotely stored in the Cloud via email.*

STATIM G4 technology

SciCan's STATIM G4 series Technology offers a platform with endless possibilities. The product expansion and modes of communication will provide visibility from every facet, from usability to troubleshooting.

This is a very exciting time for SciCan, as we are embarking into new territory with cutting edge technology. SciCan has always demonstrated innovation and this is just another example of how we are setting new standards for infection control.

*Based on your email providers storage capabilities


This model has all the benefits of our classic STATIM 2000 Cassette Autoclave

  • Ultra-fast 6 minute unwrapped cycle
  • 14 minute wrapped cycle
  • Exceptional instrument turnover
  • 10 minute Dri-Tecc Drying Technology
  • Aseptic transfer of instrument directly to the point-of-use
  • Reduced instrument investment
  • Prolongs instrument life

Like the STATIM 900, the STATIM 2000 boasts a 6-minute cycle, but has the added advantage of employing a fully removable chamber so you can aseptically transport a set of freshly sterilized instruments directly to the procedure area.

The STATIM 2000 is fully automatic. Simply select one of the three sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's STATIM cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States, and Europe.

The STATIM 2000 is a reliable cassette sterilizer that's compact enough to fit in procedure areas and fast enough to sterilize jewelry, expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just six minutes and a wrapped cycle in 14 minutes.

Dri-TecC – Convection heat drying technology

The STATIM 2000 uses convection heat to dry instruments by utilizing the remaining heat in the system after the sterilization phase. Heat is captured and released into the cassette, drying wrapped instrument loads in as little as 10 minutes.

Sterilization cycle description chart

Cycle Unwrapped Wrapped Rubber/Plastic
Sterilization time 3.5 minutes 10 minutes 15 minutes
Sterilization temp. 135º C 135º C 121º C
Total cycle time 6 minutes 14 minutes 20 minutes


ACCESSORIES available in the Shop
: see below

01-100008A Cassette complete (includes 01-106653 Instrument rack for wrapped instruments)

01-100028S Seal & lubricant kit

01-100207S Air compressor filter

01-102119S Microbiological air filter

01-100812S Waste bottle complete (includes 01-100204S Exhaust tube)

SCI134 Test Strip indicators (box of 250)

SCI-T5 Sterilization Monitor Type 5 Chemical Indicator

01-101783S Water reservoir cap & filter (Includes 01-109300S Water reservoir filter)

SPECIFICATIONS:

Unit Size : L 480mm x W 415mm x H 150mm
L 19" x W 16.25" x H 6"
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11" x W 7" x H 1.5"
Reservoir Capacity : 4.0 litres (distilled water) Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 1300 W

When you receive your Statim 2000 packing carton, the items listed below will be included.
If any of the items are missing, contact us immediately so that the situation can be corrected.

  • Cassette Tray and Lid
  • Instrument Rack
  • Waste Bottle
  • Bottle Lid Fitting
  • Exhaust Tube
  • Tube Mounting Hardware
  • Power Cord
  • Operator's Manual

STATIM G4 Cassette Autoclave In-service (United States)

An overview of installing, operating, and maintaining the SciCan STATIM G4 Cassette Autoclave


Save up to 35% off the list price of a STATIM 2000 or STATIM 5000 cassette autoclave when you use your Section 179 tax deduction: Click here for more info


*The use of STATIM sterilizers was introduced to the body art field in the early 1990's by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

Save this product for later