STATIM_G4_web_banner

STATIM 2000 G4

STATIM_G4_web_banner
SciCan_Statim_G4_grouping

SciCan_g4ff

FAST.
FORWARD.

STATIM‘s unmatched speed and dependability have made STATIM the world’s best-selling autoclave. And its patented gentle technology has made STATIM the world’s favorite.

Read more

SciCan_g4ck

UNCHANGED RELIABILITY. UNSURPASSED FUNCTIONALITY.

Dental practitioners in over 90 countries around the world rely on STATIM to protect their patients and staff from infection – with sterilized instruments in just minutes.

Read more

SciCan_g4sr

THE STATIM DIFFERENCE.

Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle.

Read more

SciCan_g4ge

TOUCH. CONNECT.
PROTECT. COLLECT.

A high-resolution, 65K color touchscreen offers a vivid display of messages, current cycle information and customizable icons all with extraordinary clarity.

Read more


scican_statim_g4_5000_top-1

FAST.

STATIM’s unmatched speed and dependability have made STATIM the world’s best-selling autoclave. And its patented gentle technology has made STATIM the world’s favourite.

FORWARD.

The STATIM G4 will offer you a level of interactivity never seen before. The STATIM G4, through its LCD touch screen control and STATIM Live networking capability, has been designed to provide you with unprecedented ease of use and puts the user in total control.

DOCTORS AROUND THE WORLD RELY ON STATIM.

Healthcare practitioners in over 90 countries around the world rely on STATIM to protect their patients and staff from infection – with sterilized instruments in just minutes. In 1989, SciCan transformed the industry, developing the world’s first compact sterilization unit designed to meet the growing need for handpiece sterilization. Today, the STATIM still boasts superior cycle times and processes for both wrapped and unwrapped cycles. In fact, the STATIM Cassette Autoclave® sterilizes up to ten times faster than traditional ‘chamber style’ units. Employing a proprietary positive pressure pulse displacement technology – using saturated steam to remove air and effectively sterilize instruments between patients – the STATIM Autoclave ensures dentists always have an ample supply of instruments ready for use.

STATIM‘S SPEED

Reduces Instrument Investment

STATIM sterilizes handpieces and instruments for immediate use in as little as 8 minutes, reducing the number required as instruments can be processed ‘just in time’ or between patients.

Increases Efficiency

Fast point-of-use sterilization makes turnaround a priority, increasing efficiency and virtually eliminates instrument bottlenecks.

Gentle on Instruments

Our state-of-the-art steam technology is gentle on both solid and hollow instruments.

scican_statim_g4_twosome

THE STATIM DIFFERENCE.

Immediate Steam Generation

Unlike conventional autoclaves that need to heat an entire reservoir of water, STATIM uses only a small, specific amount of water required for each cycle. Water is introduced into a heating device referred to as a ‘steam generator’, rapidly heated and converted to steam in mere seconds.

Air Removal

Using PPPD technology and our patented steam injection process – air is automatically forced out of the sterilization chamber.

Cassette System

The thin stainless steel walls of STATIM’s fully-removable cassette, (or sterilization chamber) allow for rapid heating and cooling of the chamber. As a result, STATIM meets the conditions for sterilization and drying in a fraction of the time required by a conventional autoclave.

Drying Technology

The STATIM 2000 and 5000 have each been designed to provide you with a complete solution: rapid sterilization balanced by rapid drying. Introducing STATIM Dri-Tec drying technology.

TOUCH. CONNECT. PROTECT. COLLECT.

scican_statim_g4_touch

TOUCH.

A large 3.5” high-resolution touchscreen offers a vivid display of messages, current cycle information and customizable colours all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-centre.

CONNECT.

Through your networked portal, you can view not only your STATIM’s current operations in real time, you can also access cycle history, printing and validation information, and also sterilization records. Capable of sending emails with cycle information errors directly to your dealer, your STATIM G4 will let qualified technicians know when service is imminent.

PROTECT.

Patient safety relies on attention to detail. The STATIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle. This encourages extra attention to process and creates a safer environment for both staff and patients.

COLLECT.

An undocumented sterilization cycle might as well not have been performed. With each cycle, information must be stored to protect your office and your patient. The integrated DataLogger stores all cycle information for the lifetime of the unit, which is accesible through multiple channels such as: a USB port for manual retrieval; an Ethernet connection for web based archiving or desktop printing; or a RS232 port for an external printer option.

SPECIFICATIONS:

Unit Size : L 495mm x W 415mm x H 150mm
L 19.5″ x W 16.25″ x H 6″
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11″ x W 7″ x H 1.5″
Reservoir Capacity : 4.0 liters (140 fl. oz.) distilled water. Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 11A 1300 W



StatClave G4

SKU G4-621103
$8,800
In stock
1
Product Details

(120V) Wifi enabled, waste water direct to drain included


This changes everything. Again.

Introducing the STATCLAVE™ Chamber Autoclave

With the reliability and trust you’ve come to expect from STATIM, the STATCLAVE G4 is designed to deliver speed, capacity and efficiency to your practice. STATCLAVE is a Class B vacuum sterilizer that incorporates both pre-sterilization vacuum to improve steam penetration and post-sterilization vacuum to improve drying. Its 11” chamber and vacuum-assisted closed-door drying efficiently delivers sterilized and dried wrapped instruments.


Fast

STAT*CLAVE* G4

STATCLAVE can efficiently sterilize and dry wrapped instrument loads in as little as 38 minutes.

Dry

Closed-door drying and vacuum technology results in perfectly dried instruments every time.

G4 Technology

SciCan’s G4 equipment can connect and send information to your smart devices or computer so you can have cycle data, instructions, and maintenance notifications at your fingertips.

Capacity

STATCLAVE’s 11” chamber can sterilize up to four full-size cassettes and 4 exam cassettes or 20 pouches with included pouch racks.

Versatile

STATCLAVE STATCLAVE offers a number of filling & draining options, including easily accessible and cleanable top reservoirs, front manual fill and a rear automatic fill option that can be connected to the VistaPure water filtration system for automated filling.

Gentle

Fresh water is used in every cycle, reducing the buildup of oils and debris.

STATCLAVE G4 Chamber Autoclave

Featuring the STATCLAVE G4 Chamber Autoclave for sterilizing dental instruments.

STATCLAVE G4 Launch at PDC 2019

Ted Gray and Melissa Summerfield discuss the latest innovation from SciCan, the STATCLAVE G4 Chamber Autoclave.

Cycle Times and Maximum Load Weights (120v)

Cycles Temperature / Time Cycle Times* Maximum Load Weight
STATCLAVE G4
Solid Unwrapped 270°F (132°C) / 4 mins 18 mins 13.2 lbs (6 kg)
Solid Wrapped 270°F (132°C) / 4 mins 44 mins 13.2 lbs (6 kg)
Hollow Unwrapped 270°F (132°C) / 4 mins 23 mins 13.2 lbs (6 kg)
Hollow Wrapped 270°F (132°C) / 4 mins 50 mins 13.2 lbs (6 kg)
Textiles/Porous 270°F (132°C) / 4 mins 49 mins 4.4 lbs (2 kg)
Rubber & Plastic 250°F (121°C) / 20 mins 36 mins 4.4 lbs (2 kg)

*Cycle time will vary depending on instrument load.

Unit Specifications

STATCLAVE G4
Unit size (L x W x H)† 25” x 17.75" x 19.5" / 635 x 450 x 495mm
Volume 6.87 gal (26 L)
Chamber Dimensions (D x L) 11" diameter, 15" depth / 297 x 381mm
Weight 61.6 kg (135.8 lbs) (without water and packaging)
Voltage 120V, 60Hz, 12 A

†On the right side, allow 2” (50mm) of space for ventilation. Allow for at least 7” (180mm) above unit to enable access to reservoirs. If less than 7” (180mm), screw on hinges can be removed to allow reservoir lid to slide in and out of position.


Download

Save this product for later

STATIM FAQs

ACCESSORIES available in the Shop:

01-100008A Cassette complete (with rack 01-106653)01-100028S Seal & lubricant kit
01-100207S Air compressor filter
01-102119S Microbiological air filter
01-100812S Waste bottle complete
01-100204S Exhaust tube
01-103945S Instrument rack for unwrapped instruments
01-106653 Instrument rack for wrapped instruments
SCI134 Test Strip indicators (box of 250)
01-101783S Water reservoir cap & filter
01-109300S Water reservoir filter

statim_2000_cassettesysTM_cassetteSurgical Plastic Sterilization TraysStat-Dri Plus

The use of STATIM sterilizers was introduced to the body art field in the early 1990’s by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

1 thought on “STATIM 2000 G4”

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.