Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

VistaPure deionized water treatment system

SKU V3000
$3,399
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
VistaPure deionized water treatment system
Product Details
Brand: SciCan
Model: Statim, StatClave, Bravo, Hydrim C, Hydrim L
Weight: 25 lbs


Your Steri-Center’s best friend.

VistaPure™ provides two grades of high-quality water for autoclaves, dental bottles,
ultrasonic cleaners and instrument washers for the ultimate convenience.


Features

Universal System

VistaPure will work with the STATIM® Cassette Autoclaves, BRAVO™ Chamber Autoclaves, HYDRIM® Instrument Washers, Ultrasonic Cleaners, Dental Bottles, other select sterilizers and automated washers.

High Quality Water

Water is autoclave-ready, distilled quality (deionized) water which eliminates the need to buy distilled water or own a distiller.

Easy to Use

VistaPure’s handheld, point-and-shoot wand makes it easy for anyone to fill autoclaves, no matter where they’re located, and the system’s mounted faucet makes it easy to fill Dental Unit bottles over a sink. We will also offer unique “automatic water filling control” options for our STATIM and BRAVO sterilizers along with our HYDRIM final rinse options.

Smart Design

VistaPure’s filter panel fits neatly under the steri-center counter with slides for easy access to the filters.

Convenient

VistaPure provides a high volume of ready-to-use water, on demand. Its large 4.25-gallon storage tank means you don’t need to wait for deionization and R/O processes to take place.

Consistent

Each VistaPure features an in-line TDS meter that monitors water quality—and also makes it easy to know when it’s time to replace your filters.

Hands Free

VistaPure accessories include patented AutoFill devices designed to replenish SciCan STATIM and BRAVO autoclaves with distilled-quality water automatically, enabling truly hands-free convenience. An optional adapter kit is also available for utilizing VistaPure’s hyper-filtered water for the final rinse cycle of instrument washers.


Articles




VistaPure Water Filtration System Two grades of high-quality water for all practice sterilization needs


Inside Dentistry, Feb 2016





VistaPure AutoFill


VistaPure’s patented AutoFill accessories replenish SciCan STATIM®and BRAVO™ autoclaves with distilled-quality water automatically — enabling truly hands-free convenience.

VistaPure AutoFill accessory kits work with all VistaPure systems and can be installed easily on any STATIM 2000/G4 or STATIM 5000/G4, or any BRAVO autoclave, in just a few minutes!


  • No more purchasing and storing distilled water

  • No more cycle-fault errors caused by forgetting to fill reservoirs

  • No more spills while filling autoclaves manually

  • No more staff time spent filling autoclaves = more time with patients

VistaPure AutoFill Installation

A 12-foot length of clear polyurethane tubing is already attached to the AutoFill manifold. If the desired distance between the connection to the VistaPure and the autoclave is greater than 12 feet, simply order a longer length of the clear polyurethane tubing, as the distance from the VistaPure to the autoclave is not limited, except by the feed tubing.

Installing AutoFill on a STATIM

The VistaPure AutoFill for STATIM device (S3020) can be installed on any STATIM 2000/G4 or STATIM 5000/G4 autoclave as follows:

https://www.scican.com/us/media/water-management/SD-491_US_EN%20R1_Autofill_Sell%20Sheet_20160805_PRNT.pdf

Installing AutoFill on a BRAVO

The VistaPure AutoFill for BRAVO device (S3030) can be installed on any model BRAVO autoclave.

In order to connect the VistaPure AutoFill to the BRAVO, one of the two tanks that come with the BRAVO must be selected as a “relay tank” since the BRAVO system uses a suction-lift pump to fill its reservoir when in its automatic-filling mode. Note that the relay tank must be located within 6 feet of the BRAVO unit, due to the suction-lift capacity of the BRAVO pump.


Connecting to a StatClave G4