Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Hydrim L110W G4 with Glass Door Instrument Washer

SKU L110W-D01-G4
$11,999
Pre-order
Out of stock, available for pre-order
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Hydrim L110W G4 with Glass Door Instrument Washer
Product Details
Brand: SciCan
Model: Hydrim L
Weight: 176 lbs

Automated Instrument Washing

the first step in the sterilization process

HYDRIM L110W G4 Instrument Washers provides a safe, effective and efficient way to clean instruments, allowing staff to focus on the most important thing in a dental practice, the patient.

HYDRIM L110W G4 Instrument Washers provides a safe, effective and efficient way to clean instruments, allowing staff to focus on the most important thing in a studio, the client.


Efficient

HYDRIM L110W G4 washer has a 10 full-size cassette capacity and will allow offices to turnover 2500 thoroughly cleaned instruments in a 10 hour day.

  • Under the counter stericenter installation with furniture available for specialized set-ups.
  • HIPTM cleaning solution is stored in the unit, no extra storage space required
  • Time saved using automated washing compared to manual cleaning is approximately 1 hour of labor for every nine procedural set-ups.1

Safe

Avoid the many steps involved with manual washing or using ultrasonic cleaners such as pre-soaking, scrubbing and drying instruments.

  • Minimize physical handling of contaminated instruments, reducing the risk of sharps injury and creating a safer work environment.
  • HYDRIM G4 technology ensures that every set of instruments receive the same validated cleaning process by dosing the correct amount of detergent with each cycle.
  • Active drying system allows instruments to immediately be transferred to the next step of instrument reprocessing, sterilization.

Smart

G4 Technology - Information at your fingertips

  • Designed as a self-monitoring unit, WiFi enabled G4 technology can connect and send cycle data to your smart devices or computer, providing easily accessible cycle data, maintenance information and service logs.
  • G4 technology connects your HYDRIM to specialized technicians, which allows for remote support and minimizes unnecessary downtime.
  • Large touch screen gives in-depth cycle info and allows users to view current operation.

Instrument Processing with HYDRIM Automated Instrument Washers

Ted Gray and Melissa Summerfield discuss one-direction flow instrument processing and the use of HYDRIM Automated Instrument Washers along with STATIM and Bravo autoclaves. @PDC2018

HYDRIM L110W G4 In-Service


An overview of installing, operating, and maintaining the SciCan HYDRIM L110W Instrument Washer.

Specifications

HYDRIM L110W G4
Unit Size: (W x H x D) 598 x 850 x 600 mm
(23.54" x 33.5" x 23.75")
Cycle Times*
Rinse and Hold 17 mins
Regular Wash + Dry 25 mins + 10 mins
Heavy Duty Wash + Dry 34 mins + 10 mins
Electrical Rating: 208 – 240V, 15A, 60 Hz
Weight 80 kg / 176 lbs
Disinfection Cycle x
Built in accordance to ISO15883-1 & -2 x

*Actual cycle times will vary with incoming water temperature and pressure.

Included Accessories

Part Number Description Quantity
01-109967S Hygiene Basket 1
01-113547 Basket with Hinged Lid 1
01-109963S 5 Cassette Rack 1
01-109964S 5 Cassette Rack, Half Size 1
CS-HIPL Box of HIP Cleaning Solution 1
USB 1

Download

Articles

Product Insights: HYDRIM G4 Automated instrument washing enhances efficiency and safety, by Inside Dentistry

product="" dentistry="">

Brochure

HYDRIM Brochure C61W G4 & L110W G4

HYDRIM L110W G4 Sell Sheet

E-Book

Top 5 Ways to Automate Steri-Center Operations by Dental Products Report

Manual

HYDRIM L110W G4 Operator’s Manual

HYDRIM L110W G4 Quick Reference Guide


Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.