Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Ensure Autoclave Monitoring

SKU SCI-BISK-120
$413.50
Preorder
Ensure
Out of stock, available for pre-order
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Ensure Autoclave Monitoring
Product Details
Brand: SciCan
Model: Ensure
UPC: SCI-BISK-120
Weight: 3 lbs

Think of it as a routine checkup for your sterilizer.

The ENSURE line of Infection Control monitoring products ensures your equipment is performing at its peak. It includes a range of products that are simple, easy-to-use, and help to ensure your clients are being kept safe with every cycle.

The Incubator

The unique incubator allows you to monitor up to 5 sterilizers at one time, providing you with easy to read results that show whether sterility has been achieved... or not. The ENSURE system can satisfy even the most stringent international regulatory requirements.

No need to wonder, when it’s this easy to know. The ENSURE Incubator, a 10-well incubator, is a very unique unit unlike any in the market today. With an integrated vial crusher and built in timer for up to five different programs, the SciCan ENSURE BI system leaves no room for error in time.

Biological Indicators (BI) "Spore Tests"

The ENSURE BI’s are fast, reliable, self-contained indicators for results in as little as 24 hours. BI’s are the only cost effective method to ensure effective performance of your sterilizer.

The ENSURE BI’s are available in a starter kit system that consist of 25 BI’s, the unique incubator and an easy to fill-in log book. The starter kit is the most cost effective, accurate system for monitoring your steam autoclave directly in your office in only 24 hours.

Specification

Part Number
Description
SCI-134 Class 4 ENSURE CI strips 132-134°C (250 count)
SCI-BI25 ENSURE BI's (25 count refill box)
SCI-BI100 ENSURE BI's (100 count refill box)
SCI-BISK-120 ENSURE system, Starter kit (25 BI's, incubator, log book)
SCI-BINC-120 ENSURE incubator (incubator only)
SCI-BILOG ENSURE BI monitoring system log book (PDF Download)

Ensure SDS