Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

STATIM 5000 Maintenance Kit

SKU 01-115326S
$254.76
Bulk pricing available for quantities of 10 units or more
Each kit contains the three components that are required to be replaced every 6 months (or 500 cycles) in order to maintain optimal performance of your STATIM
Would you like to buy this product one time or subscribe for it?
In stock
1
Buy more, save more
QuantityPrice per itemDiscount
10 items$22014% off
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
STATIM 5000 Maintenance Kit
Product Details
Brand: SciCan
Model: 5000, 5000 G4, 5000S
Weight: 1 lbs

We are pleased to announce the introduction of a new Maintenance Kit for your STATIM 2000 G4 and 5000 G4 autoclave, which will allow for easier ordering of parts required for regular maintenance.

Each kit contains the following three components that are required to be replaced every 6 months (or 500 cycles) in order to maintain optimal performance of your STATIM:

  • Cassette seal and lubricant (also sold separately as part number 01-101649S for STATIM 5000)
  • Biological filter (also sold separately as part number 01-102119S, compatible with both STATIM 2000 and STATIM 5000):
  • Air compressor filter 01-101652S

NOTE: SciCan Green, with the STATIM name embossed on the seal, to make them easy to tell apart from the imitations! Read More

Seals should be changed every 500-800 cycles or every six months (whichever is first).

Air filters should be changed every 500 cycles or every six months (whichever is first)


  • Includes detailed instructions and high purity mineral oil for seal lubricant.
  • (SDS download with purchase)

Every 6 months

Cassette Seal • Replace every 500 cycles or six months (whichever is first), or whenever necessary. Video: How to change the cassette seal
Biological and/or Air Filter • Replace every 500 cycles or six months

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.