Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Statim 2000 USED / REFURBISHED

SKU 2000SPECIAL
$3,760
Preorder
Estimated delivery time
Shipping: 47–178 days
Pickup: 32–123 days
Out of stock, available for pre-order
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Statim 2000 USED / REFURBISHED
Product Details
Brand: SciCan
Model: 2000 Classic
Weight: 54 lbs

STATIM 2000 Cassette Autoclave


Reconditioned used units validated and spore tested with one year warranty

  • Ultra-fast 6 minute unwrapped cycle
  • 14 minute wrapped cycle
  • Exceptional instrument turnover
  • 10 minute Dri-Tecc Drying Technology
  • Aseptic transfer of instrument directly to the point-of-use
  • Reduced instrument investment
  • Prolongs instrument life

The STATIM 2000 Classic boasts a 6-minute cycle, but has the added advantage of employing a fully removable chamber so you can aseptically transport a set of freshly sterilized instruments directly to the procedure area.

The STATIM 2000 is fully automatic. Simply select one of the three sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's STATIM cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States, and Europe.

The STATIM 2000 is a reliable cassette sterilizer that's compact enough to fit in procedure areas and fast enough to sterilize jewelry, expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just six minutes and a wrapped cycle in 14 minutes.

Dri-TecC Convection Heat Drying for the STATIM 2000

Dri-TecC – Convection heat drying technology

The STATIM 2000 uses convection heat to dry instruments by utilizing the remaining heat in the system after the sterilization phase. Heat is captured and released into the cassette, drying wrapped instrument loads in as little as 10 minutes.

Sterilization cycle description chart

Cycle Unwrapped Wrapped Rubber/Plastic
Sterilization time 3.5 minutes 10 minutes 15 minutes
Sterilization temp. 135º C 135º C 121º C
Total cycle time 6 minutes 14 minutes 20 minutes

ACCESSORIES available in the Shop:

01-100008A Cassette complete (with rack 01-106653)
01-100028S Seal & lubricant kit
01-100207S Air compressor filter
01-102119S Microbiological air filter
01-100812S Waste bottle complete
01-100204S Exhaust tube
01-103945S Instrument rack for unwrapped instruments
01-106653 Instrument rack for wrapped instruments
SCI134 Test Strip indicators (box of 250)
01-101783S Water reservoir cap & filter
01-109300S Water reservoir filter

statim_2000_cassettesysTM_cassetteSurgical Plastic Sterilization TraysStat-Dri Plus

SPECIFICATIONS:

Unit Size : L 480mm x W 415mm x H 150mm
L 19" x W 16.25" x H 6"
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11" x W 7" x H 1.5"
Reservoir Capacity : 4.0 litres (distilled water) Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 1300 W

When you receive your Statim 2000 packing carton, the items listed below will be included.
If any of the items are missing, contact us immediately so that the situation can be corrected.

  • Cassette Tray and Lid
  • Unwrapped Instrument Rack
  • Waste Bottle
  • Bottle Lid Fitting
  • Power Cord
  • Operator's Manual
  • Exhaust Tube
  • Tube Mounting Hardware

Finance your equipment at our checkout

*The use of STATIM sterilizers was introduced to the body art field in the early 1990's by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

Leave a Comment