Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

Repair Labor

SKU REPAIR
$400
We fix it for you 🔧🪛
Model number
Enter your text
Serial number
Enter your text
Issues Noted: Please list error codes and any parts or service work completed in the field below. Reason for repair ( Please provide specific detailed information **'Not working' and 'Defective' are NOT acceptable**)*
Enter your text
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
Repair Labor
Product Details
Brand: SciCan

We will repair your STATIM or other SciCan equipment

For your SciCan product repair we will need the following details: your serial number which should be on the back of the unit, and a description of the issues noted such as cycle fault numbers, sounds or visible damage.

With this information we will provide you with a return authorization number and the best shipping address for where to send the equipment.

*The minimum estimate fee is $150 in case the estimate is refused and equipment is to be returned unrepaired or destroyed/recycled.


**ONE SERIAL NUMBER & PO PER REQUEST (PO NUMBER CANNOT BE DUPLICATED FOR MULTIPLE UNITS)

This Repair Form is for Equipment only – If you are sending in a Handpiece, please fill out the “Handpiece Repair Form".

Please note, the RA number must be on the outside of the box.

Any machines returned to SciCan without an RA number will be returned.


Shipping the Statim Unit

You must write your RMA number clearly on the outside of the package
Before you move the unit, you will need to drain the reservoir. To do so, follow these steps:
  1. Place a water container below the unit.
  2. Using the drain tube (see Section 3.5 Priming the Statim Pump, Figure 6 in the manual) empty the contents of the reservoir into the water container.
  3. Remove any remaining water from the reservoir with a non-linting, absorbent towel.
  4. Screw-in the three leveler feet found underneath the unit.
  5. Repack the unit in the original packing materials and include all accessories originally included with the unit.
  6. Specify heated and insured shipping.


Make sure to include ALL cassettes used with this unit. The cassettes must be shipped with the unit for calibration.
Note: Do not ship the unit with a cassette inserted.

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.