Introducing SciCan OPTIM OS1 Liquid

Rapid contact times for best results

  • 60-second kill times for viruses, bacteria, and yeast
  • Kills TB Bacteria in only 45 seconds and Candida auris in 60 seconds

Safe for use on hard, non-porous clinical surfaces

  • Cleans and disinfects stainless steel, anodized aluminum, non-porous upholstery, Corian countertops, silicone, and more

Formulated with the user in mind

  • VOC-free, fragrance-free and dye-free

Emerging Pathogen Claim ensures your clinic is ready for the next viral
threat

  • Qualifies for EPA’s Emerging Viral Pathogen Claim
  • Kills SARS-CoV-2, the virus that causes COVID-19, in only 30 seconds

You can learn more about OPTIM’s newest formula below

> Product Brochure EN

> Safety Data Sheet (Wipes) EN

> Safety Data Sheet (Liquid) EN

> Manual Instructions for Use EN

OPTIM OS1 Wipes Quick Reference Guide

OPTIM OS1 SOLUTION Liquid Spray

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.

Spray Ready-to-Use OPTIM OS1 liquid onto a SciCan Dry Towelette. Do not directly spray onto the surface.


If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one
towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

OPTIM OS1 Ready-to-Use Wipes

Pull out OPTIM OS1 towelette at a 45 degree angle. Close lid.

If surface is not heavily soiled, clean and disinfect surface with one wipe and allow surface to remain wet for the contact time indicated on the label.

If surface is visibly soiled, clean surface with one towelette and discard. Use a second towelette to disinfect and allow surface to remain wet for the contact time indicated on the label.

Procedure for disinfecting PVS elastomeric impression materials with OPTIM OS1

  1. Once the impression is taken, rinse it well under running tap water to remove blood and saliva.
  2. After rinsing, gently shake the impression within the sink basin to remove any adherent water with minimal splatter.
  3. Spray the entire impression with OPTIM OS1. Use the contact times as stated on the label.
  4. Rinse the impression thoroughly with tap water to remove any excess disinfectant. After a thorough rinse, gently
    shake the impression inside the sink basin to remove any adherent water with minimal splatter.
  5. Once dry, place the disinfected impression in a sealed bag.
    The impression is now safe and ready for further processing.
PVS elastomeric impression materials

Switching to OPTIM OS1

  • Give all surfaces a good cleaning with soap and water before switching to OPTIM OS1.
  • After switching to OPTIM OS1, surfaces should to be periodically rinsed with water (recommended no less than once per week).
  • Common practice for all chemical disinfectants is to periodically rinse and dry surfaces to maintain the surface integrity.
  • Avoid mixing of chemistries.

HYDRIM 112W G4+ Automated Instrument Washer

SKU G4-W10001
$13,890
NEW
In stock
1
Save this product for later
Have questions?
Share this product with your friends
Customer reviews
Reviews only from verified customers
No reviews yet. You can buy this product and be the first to leave a review.
HYDRIM 112W G4+ Automated Instrument Washer
Product Details
Brand: SciCan
Model: HYDRIM 112W G4+ Automated Instrument Washer
Weight: 143 lbs

Introducing the New HYDRIM 112W G4+ Automated Instrument Washer

Cleaning is the critical first step in instrument reprocessing. As the leader in Infection Control, SciCan is proud to introduce the next generation in a legacy of best-in-class instrument washers with the HYDRIM 112W G4+ Automated Instrument Washer. With its large 112-liter chamber, efficient cleaning times, and flexible loading configurations, the HYDRIM 112W provides a host of features to increase productivity, improve cleaning effectiveness, and decrease exposure to injury.

Optimized workflow

  • Unlike manual cleaning (which requires pre-soaking, hand-scrubbing, rinsing, and drying each instrument), the HYDRIM 112W takes care of rinsing, washing, and drying – so your staff can spend more time with patients
  • Save money with a lower cost of use compared with manual or ultrasonic cleaning
  • Fast and efficient cycle times allow for more instruments to be cleaned per cycle than the leading competitor and vs. manual or ultrasonic cleaning
  • Uses 33% less water per cycle than the leading competitor

Lower sharps risks

  • Reduce the risk of sharps injuries, particularly when paired with cassette systems
  • Powerful and consistent cleaning
  • Cleans, rinses, and dries a full load (as many as 250 instruments) in as little as 44 minutes
  • Integrated HIP cleaning solution is stored within the unit and is automatically dispensed each cycle for validated and hassle-free cleaning
  • Closed-door, HEPA-filtered drying ensures instruments are dry and sterilization-ready after every cycle

Easy to use, all-in-one solution

  • A large, 5” glove-friendly touchscreen allows for detailed cycle information, maintenance reminders, and video tutorials
  • Vivid, LED color status indicator provides quick and easy interpretation of wash cycle status to minimize unnecessary trips in and out of the Stericenter
  • Ready-to-use on day one with cleaning solution, cassette racks, and baskets provided – no additional purchase necessary

Complete connectivity

  • As a WiFi- and ethernet-enabled device, the HYDRIM 112W provides access to myCOLTENE, our web-based digital platform that empowers staff with helpful tutorials, maintenance videos, support materials, software updates and more

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.