OPTIM 33TB cleaning protocol

SciCan_OPTIM_USA

OPTIM™33 TB Quick Reference Guide

SWITCHING TO OPTIM 33 TB

Give all surfaces a rinse with mild soap & water before switching to OPTIM.

SciCan_OPTIM_USAQUATs (Quaternary Ammonium Compounds) or phenol based disinfectants are common active ingredients in the dental operatory today and are known to leave residual active chemistry on surfaces. AHP (Accelerated Hydrogen Peroxide) is an oxidizer and will remove chemical residues left by other surface disinfectants. There may be odor or film development if surfaces are not rinsed (damp wiped) properly with soap & water. This odor or film should however dissipate on average within 7 to 10 days of continual use as AHP will remove the residual active ingredient.

Surfaces need to be periodically rinsed with water!

Dissents or complaints happen when users are not informed on the correct protocol when using the product. It is good practice to periodically (at least once a week) rinse or wipe surfaces with a damp cloth to remove surfactants (detergents) or residual active ingredients that can build up over time with the use of ANY disinfectant cleaner.

No mixing of chemistries!

Mixing of chemistries in operatory i.e. using quats-alcohol/phenol disinfectant and OPTIM 33 TB in the same operatory or refilling OPTIM into chemical container used previously for other chemicals is not recommended. It is best practice to never mix chemistries (any kind) no matter what industry you are in.

On which surfaces can OPTIM 33 TB be used?

Non-porous hand contact environmental surfaces including Naugahyde (vinyl coated upholstery fabric).

NOTE: Soft surfaces such as chairs and cables should be periodically rinsed with water or wiped with a damp cloth to prevent the build-up of disinfectant or surfactants. As best practice, for any kind of disinfectant or cleaners used, chairs should be wiped with a damp cloth at the end of the day or at least once a week.

PRECAUTIONS:

– Surfaces that are composed of brass or copper, or other ferrous metals may show signs of discoloration or pitting with prolonged exposure.

– Anodized aluminum (often used on hand-pieces) and carbon tipped instruments should be avoided (i.e. burrs). Material impact can be reduced with rinsing or damp wiping.

We advise against wrapping gauze pad or ‘sleeves’ soaked in disinfectant on hand-pieces.


OPTIM 33 TB Solution

OPTIM 33TBSpray – Wipe – Spray Protocol

Visibly Soiled Surface – Clean before disinfecting

  1. Spray OPTIM 33 TB directly onto surface.
  2. Wipe visible soil with Stat-Wipes or clean paper towel to clean surface.
  3. Discard soiled towelette.
  4. Continue to disinfection step

Visibly Clean Surface – Disinfect pre-clean surface

  1. Spray OPTIM 33TB to cover the pre-clean surface. Allow the disinfectant to remain
  2. undisturbed on the surface for the contact time indicated on the label.
  3. *Do not overspray as this can create pooling of liquid. OPTIM 33TB is water based not alcohol based.
  4. Wipe with Stat-Wipes or clean paper towel.
  5. Discard used towelette.

*Using gauze dipped in solutions for wiping can cause pooling of liquid on surface. Wipe surface dry with paper towel if surface is still wet after desired contact time is achieved.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One- Step Cleaner Disinfectant. Therefore, OPTIM can be used on visibly clean surface. Depending on the soil load on the surface, the 2 step process is not required due to this EPA claim.


OPTIM 33 TB Wipes

Standard Protocol for Visibly Soiled Surface

Clean before disinfecting

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Clean surface with towelette to remove organic matter or visible blood.
  3. Discard used towellete.

Disinfect After Cleaning

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Disinfect surface with towelette.
  3. Allow surface to remain wet for the recommended contact time.
  4. Discard used towelette.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One-Step Cleaner Disinfectant. Depending on the soil load on the surface, users have the choice of cleaning the surface with one side of the wipe and disinfecting the surface with the reverse side of the wipes. Always allow surface to remain wet for the recommended contact time.

Because OPTIM 33 TB is approved as a One-Step Cleaner Disinfectant, depending on the soil load, the 2 step process may not be required due to this EPA claim.

Get Optim in our Store

VistaCool direct-to-drain systems

V7601
$999
Pre-order
1
Product Details
Brand: SciCan
Model: 2000, 5000, 900

Never empty your STATIM condenser bottle again!

VistaCool - the only direct-to-drain system designed from the ground up for your STATIM 2000 and 5000 cassette autoclaves. VistaCool eliminates the need for autoclave condenser bottles by cooling sterilizer wastewater and sending it directly down the drain automatically.

Protect Cabinets

Helps prevent mold, mildew, rot and rust caused by spills and humid environments created by exhaust from condenser bottles.

Protects Drains

Prevents autoclave wastewater from damaging plumbing. Built-in backflow prevention meets or exceeds local plumbing codes..

Protects Staff

Eliminates the need for office staff to empty hot water bottles manually.

Saves Time


Install Anywhere

The innovative design of the new VistaCool 3 provides all the same benefits as its predecessors, while occupying less space. The system’s included mounting clips and pressurized drain line enable it to be installed vertically or horizontally in almost any location.

  • FAST Drains STATIM exhaust safely and automatically.
  • EFFICIENT Eliminates wasted staff time emptying condenser bottle.
  • COST EFFECTIVE Dedicate more resources to patient care and less on maintenance

SciCan VistaCool Sophisticated wax motor allows cold water into the system ONLY when the sterilizer is in use.

FEATURES
UNIVERSAL SYSTEM
VistaCool will work with the STATIM 2000 or 5000 and other select sterilizers.
ROBUST
System will continuously cool your STATIM’s hot exhaust and drain it safely – no matter how many cycles you run.
VALIDATED
VistaCool is the only direct-to-drain product designed to safely and effectively drain the steam exhaust from a STATIM 2000 or 5000 and other select sterilizers.

SMART DESIGN
Triangular water tank is shaped to take up less space under your sink. Double unit services two sterilizers. No counter drilling or air gap (in most cases).

COMPLIANT
All components and system set-up are compliant with most regional plumbing codes.

COMPATIBLE
Can be used with all drainage pipe material types.
ECO DESIGN
Water tank is made of recycled plastic material.
EASY TO USE
No consumable parts and no daily maintenance is required.

Over the last 20 years, the STATIM cassette autoclave is one of the quintessential innovations in sterilization technology and enjoys leadership in the body art, dental and ophthalmology markets in over 90 countries. Designed to sterilize in a fraction of the time compared to traditional autoclaves, the STATIM reduced the quantity of expensive instruments needed.

To enhance the STATIM functionality, SciCan is proud to introduce the latest innovation to the STATIM brand: the VistaCool. The VistaCool is a direct-to-drain system whereby the STATIM is connected directly to the office or clinic plumbing. What this means is, rather than the STATIM unit draining into the external drainage bottle, the STATIM can now vent the used sterilization water directly down the main office drain.

There are many benefits of venting the STATIM unit directly down the drain, most notably saving time and increasing office efficiency. The VistaCool will save time, as a staff person will no longer be responsible for regularly emptying the bottle.

The VistaCool uses cold city water to cool the steam quickly and efficiently. The thermal sensor only activates when the system is in use, so water is only used when it’s needed. The built-in safety feature prevents the system from overheating and damaging office cabinetry.

Specifications

V7501 V7502 V7601
Tank Material Polyethylene – Gray Gray ABS Tank, PVC End Caps
Tank Dimensions 10.75" W x 5.75" L x 13.75" H 4.0" W x 13.0" L x 17.0" H 3.5" Diameter x 15.0" L
Tank Volume 1.50 Gallons / 5.70 Liters 3.00 Gallons / 11.40 Liters 0.37 Gallons / 1.40 Liters
Tank Weight (w/ water & Fittings) 15.0 lbs. / 6.8 kg 28.0 lbs. / 12.7 kg 5.0 lbs. / 2.3 kg
Coolant Water Connection Supply fittings for 1/4" O.D. feed tubing included.
Drain/Wastewater Connection Drain tee with fittings included. Not included.
Max Coolant Water Pressure 100 psi / 6.9 bar
Max Altitude (If using Air Gap) 6,561 feet / 2000 meters

Download