OPTIM 33TB cleaning protocol

SciCan_OPTIM_USA

OPTIM™33 TB Quick Reference Guide

SWITCHING TO OPTIM 33 TB

Give all surfaces a rinse with mild soap & water before switching to OPTIM.

SciCan_OPTIM_USAQUATs (Quaternary Ammonium Compounds) or phenol based disinfectants are common active ingredients in the dental operatory today and are known to leave residual active chemistry on surfaces. AHP (Accelerated Hydrogen Peroxide) is an oxidizer and will remove chemical residues left by other surface disinfectants. There may be odor or film development if surfaces are not rinsed (damp wiped) properly with soap & water. This odor or film should however dissipate on average within 7 to 10 days of continual use as AHP will remove the residual active ingredient.

Surfaces need to be periodically rinsed with water!

Dissents or complaints happen when users are not informed on the correct protocol when using the product. It is good practice to periodically (at least once a week) rinse or wipe surfaces with a damp cloth to remove surfactants (detergents) or residual active ingredients that can build up over time with the use of ANY disinfectant cleaner.

No mixing of chemistries!

Mixing of chemistries in operatory i.e. using quats-alcohol/phenol disinfectant and OPTIM 33 TB in the same operatory or refilling OPTIM into chemical container used previously for other chemicals is not recommended. It is best practice to never mix chemistries (any kind) no matter what industry you are in.

On which surfaces can OPTIM 33 TB be used?

Non-porous hand contact environmental surfaces including Naugahyde (vinyl coated upholstery fabric).

NOTE: Soft surfaces such as chairs and cables should be periodically rinsed with water or wiped with a damp cloth to prevent the build-up of disinfectant or surfactants. As best practice, for any kind of disinfectant or cleaners used, chairs should be wiped with a damp cloth at the end of the day or at least once a week.

PRECAUTIONS:

– Surfaces that are composed of brass or copper, or other ferrous metals may show signs of discoloration or pitting with prolonged exposure.

– Anodized aluminum (often used on hand-pieces) and carbon tipped instruments should be avoided (i.e. burrs). Material impact can be reduced with rinsing or damp wiping.

We advise against wrapping gauze pad or ‘sleeves’ soaked in disinfectant on hand-pieces.


OPTIM 33 TB Solution

OPTIM 33TBSpray – Wipe – Spray Protocol

Visibly Soiled Surface – Clean before disinfecting

  1. Spray OPTIM 33 TB directly onto surface.
  2. Wipe visible soil with Stat-Wipes or clean paper towel to clean surface.
  3. Discard soiled towelette.
  4. Continue to disinfection step

Visibly Clean Surface – Disinfect pre-clean surface

  1. Spray OPTIM 33TB to cover the pre-clean surface. Allow the disinfectant to remain
  2. undisturbed on the surface for the contact time indicated on the label.
  3. *Do not overspray as this can create pooling of liquid. OPTIM 33TB is water based not alcohol based.
  4. Wipe with Stat-Wipes or clean paper towel.
  5. Discard used towelette.

*Using gauze dipped in solutions for wiping can cause pooling of liquid on surface. Wipe surface dry with paper towel if surface is still wet after desired contact time is achieved.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One- Step Cleaner Disinfectant. Therefore, OPTIM can be used on visibly clean surface. Depending on the soil load on the surface, the 2 step process is not required due to this EPA claim.


OPTIM 33 TB Wipes

Standard Protocol for Visibly Soiled Surface

Clean before disinfecting

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Clean surface with towelette to remove organic matter or visible blood.
  3. Discard used towellete.

Disinfect After Cleaning

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Disinfect surface with towelette.
  3. Allow surface to remain wet for the recommended contact time.
  4. Discard used towelette.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One-Step Cleaner Disinfectant. Depending on the soil load on the surface, users have the choice of cleaning the surface with one side of the wipe and disinfecting the surface with the reverse side of the wipes. Always allow surface to remain wet for the recommended contact time.

Because OPTIM 33 TB is approved as a One-Step Cleaner Disinfectant, depending on the soil load, the 2 step process may not be required due to this EPA claim.

Get Optim in our Store

Lumen water distiller cleaner

6603
$38
In stock
1
Product Details
Brand: Pure Scientific

Lumen Water Distiller Cleaner and Descaler is used to remove mineral deposits in the boiling tank of your water distiller. It’s important to clean your water distiller’s boiling tank every month or after making 30 gallons of water. Regular maintenance improves the functioning and longevity of your Pure Scientific Water Distiller.

  • Improves heating element performance
  • Regular maintenance improves longevity of machine
  • Descales and removes mineral buildup
  • Maintains a clean appearance
  • Improves boiling tank appearance
  • May be used to descale other items like tea pots*

(*If item has electronic components please check manual before using)


*Will ship separately by FedEx ground.

NOTE: LUMEN CAN ONLY SHIP GROUND IN CONTINENTAL U.S. AND CANNOT BE RETURNED.

How To Clean Your Boiling Tank – Mini Classic Water Distiller

Cleaning the Boiling Chamber:

Sometimes scale will build up inside the boiling chamber. This needs to be removed periodically to ensure good heating element life, and high-quality water. NOTE: If you rinse the boiling chamber every time you fill it, it will help reduce the maintenance needed.

NOTE: If you live in a "soft water area," or you have a water softener, your unit may rarely need cleaning.

To Clean the Boiling Chamber:

1. Turn the power switch to the OFF position.

2. If the unit has been operating, allow it to cool for 30 minutes from the end of the distillation cycle.

3. Carefully remove the boiling chamber from the unit.
CAUTION: The boiling chamber will get hot and could cause a burn if the unit has not been allowed to cool.

4. Remove the boiling chamber lid (4).

5. Drain any residual water inside the boiling chamber (1).

6. Fill the boiling chamber to the water level indicator (2).

7. Add Lumen Cleaner (stock #6603) to the boiling chamber. Follow instructions on the label.

NOTE: DO NOT replace the boiling chamber back into the unit during the cleaning process. DO NOT allow the unit to operate with the Lumen Cleaner in the boiling chamber.

Lumen

Mix 2 tablespoons of the Lumen Cleaner formula with water and pour the solution into the boiling tank. Let the solution sit overnight. Next day, get rid of the residues, rinse off the boiling tank, clean it, fill it up with water up to the water level indicator, run the first batch, discard and then you are good to start producing distilled water.


Sorry, we cannot ship this product to Hawaii, Alaska or internationally.

This item can NOT be returned.

NOTE: This product contains hazardous materials