OPTIM 33TB cleaning protocol

SciCan_OPTIM_USA

OPTIM™33 TB Quick Reference Guide

SWITCHING TO OPTIM 33 TB

Give all surfaces a rinse with mild soap & water before switching to OPTIM.

SciCan_OPTIM_USAQUATs (Quaternary Ammonium Compounds) or phenol based disinfectants are common active ingredients in the dental operatory today and are known to leave residual active chemistry on surfaces. AHP (Accelerated Hydrogen Peroxide) is an oxidizer and will remove chemical residues left by other surface disinfectants. There may be odor or film development if surfaces are not rinsed (damp wiped) properly with soap & water. This odor or film should however dissipate on average within 7 to 10 days of continual use as AHP will remove the residual active ingredient.

Surfaces need to be periodically rinsed with water!

Dissents or complaints happen when users are not informed on the correct protocol when using the product. It is good practice to periodically (at least once a week) rinse or wipe surfaces with a damp cloth to remove surfactants (detergents) or residual active ingredients that can build up over time with the use of ANY disinfectant cleaner.

No mixing of chemistries!

Mixing of chemistries in operatory i.e. using quats-alcohol/phenol disinfectant and OPTIM 33 TB in the same operatory or refilling OPTIM into chemical container used previously for other chemicals is not recommended. It is best practice to never mix chemistries (any kind) no matter what industry you are in.

On which surfaces can OPTIM 33 TB be used?

Non-porous hand contact environmental surfaces including Naugahyde (vinyl coated upholstery fabric).

NOTE: Soft surfaces such as chairs and cables should be periodically rinsed with water or wiped with a damp cloth to prevent the build-up of disinfectant or surfactants. As best practice, for any kind of disinfectant or cleaners used, chairs should be wiped with a damp cloth at the end of the day or at least once a week.

PRECAUTIONS:

– Surfaces that are composed of brass or copper, or other ferrous metals may show signs of discoloration or pitting with prolonged exposure.

– Anodized aluminum (often used on hand-pieces) and carbon tipped instruments should be avoided (i.e. burrs). Material impact can be reduced with rinsing or damp wiping.

We advise against wrapping gauze pad or ‘sleeves’ soaked in disinfectant on hand-pieces.


OPTIM 33 TB Solution

OPTIM 33TBSpray – Wipe – Spray Protocol

Visibly Soiled Surface – Clean before disinfecting

  1. Spray OPTIM 33 TB directly onto surface.
  2. Wipe visible soil with Stat-Wipes or clean paper towel to clean surface.
  3. Discard soiled towelette.
  4. Continue to disinfection step

Visibly Clean Surface – Disinfect pre-clean surface

  1. Spray OPTIM 33TB to cover the pre-clean surface. Allow the disinfectant to remain
  2. undisturbed on the surface for the contact time indicated on the label.
  3. *Do not overspray as this can create pooling of liquid. OPTIM 33TB is water based not alcohol based.
  4. Wipe with Stat-Wipes or clean paper towel.
  5. Discard used towelette.

*Using gauze dipped in solutions for wiping can cause pooling of liquid on surface. Wipe surface dry with paper towel if surface is still wet after desired contact time is achieved.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One- Step Cleaner Disinfectant. Therefore, OPTIM can be used on visibly clean surface. Depending on the soil load on the surface, the 2 step process is not required due to this EPA claim.


OPTIM 33 TB Wipes

Standard Protocol for Visibly Soiled Surface

Clean before disinfecting

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Clean surface with towelette to remove organic matter or visible blood.
  3. Discard used towellete.

Disinfect After Cleaning

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Disinfect surface with towelette.
  3. Allow surface to remain wet for the recommended contact time.
  4. Discard used towelette.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One-Step Cleaner Disinfectant. Depending on the soil load on the surface, users have the choice of cleaning the surface with one side of the wipe and disinfecting the surface with the reverse side of the wipes. Always allow surface to remain wet for the recommended contact time.

Because OPTIM 33 TB is approved as a One-Step Cleaner Disinfectant, depending on the soil load, the 2 step process may not be required due to this EPA claim.

Get Optim in our Store

Emergency Vehicle Personal Purifier

EVPP
$299
NASA spinoff technology for your procedure space or car
In stock
1
Product Details
Brand: OSO-Pure

The EVPP is the perfect Air Purifier for your desktop workspace, work or personal vehicles. Utilizing Electro Static Plasma (ESP) along with Negative Ionization Technologies to purify air and surfaces reducing up to 98% of Bacteria, Viruses, Mold, Mildew, and other contaminants. Odors like smoke are also eliminated, creating a cleaner safer personal area.



Applications

The EVPP is ideal for:

  • Personal Desk or Cubicle
  • Work Stations
  • Personal Area or space of any kind
  • Work vehicles such as
    • Ambulance
    • Police & State Cruisers
    • Personal vehicle

About the technology

EVPP’s Electro Static Plasma (ESP) create cluster oxidizers along with single Ionization to purify the surrounding air. ESP replicates nature’s purifying process that incapacitate microbes via cell lysing or by changing the molecular structure of chemical contaminants making this portable purification system one of the most effective technologies available today.

Benefits

Compact, fits on dash or desk, integrated solar power, auto on/off sensor

Includes: car adaptor, anti-skid mat and adhesive applicators. (Desktop 110v AC & Auto 12v DC adaptor included)

*1 Year Warranty*


Meets or Exceeds: EPA, FDA, OSHA & NIOSH National Government Safety Standards

Features

  • No maintenance cost or consumables
  • Quiet operation
  • Low energy consumption and integrated solar power
  • Removes unwanted odors

Contaminant Removal

  • Pathogens
    • Bacteria & Virus
  • Particulates
    • Dust & Allergens
  • Volatile Organic Compounds (VOC)
    • Resins & Formaldehydes
  • Chemically Active Compounds (CAC)
    • Solvents & Compounds

EVPP Specifications

Performance
Airflow: up to 4.4 CFM
Coverage: 35-94 cubic feet
Electrical 110 VAC / plug-adapt
12V DC / car adaptor
Warranty 1 Year
Width in 7.5″
Depth in 5.5″
Height in 1.75″
Operating Environment
Temp 34 to 148 Fahrenheit
Humidity ≤ 80% RH
Save this product for later