Stat-Dri Plus

STAT-DRI Plus Drying / Rinse Agent For faster drying

For faster drying and seal lubrication coat the STATIM Cassette: After cleaning and drying the cassette, treat the interior surfaces with STAT-DRI Plus.
Add to the rinse aid dispenser on your HYDRIM instrument washer for effective drying results. Use StatDri Plus Drying agent for dramatically improved STATIM, BRAVO and HYDRIM drying and to extend the life of your STATIM seal.

You’ll notice the difference on your first cycle!

Stat-Dri Use Protocol

STATIM 2000/5000 Operator’s Manual 95-108027 Rev 5.0.
Copyright 2008 SciCan Ltd . All rights reserved.

3.9 Preparing Unit for Use

Once the unit is installed and before any instruments are sterilized, run two Wrapped Cycles (see Section 4.8 Statim 2000 – Running a Cycle and 4.10 Statim 5000 – Running a Cycle). Remove the cassette once it has cooled. Clean the top (lid) and bottom (tray) sections using a soft cloth to wipe the inside surfaces and then rinse thoroughly with tap water. Once the cassette is clean and dry, coat the inside surfaces with STAT-DRI.

STAT-DRI

Treatment of the interior surfaces of the cassette with the STAT-DRI drying agent, provided with your unit, will enhance the drying process. (Replacement bottles are available from SciCan, order number 2OZPLUS, 8OZPLUST, 32OZPLUS).

4.3 Statim 5000 — STAT-DRI Plates

The Statim 5000 cassette uses STAT-DRI plates to enhance the drying process for wrapped instruments. The adjustable plates are designed for the unwrapped instruments rack and eliminate the need for a separate wrapped instrument rack. Up to ten plates can be arranged along the length of the rack. Each unit is shipped with five STAT-DRI plates. Additional plates may be ordered from SciCan (SciCan part number 01-103935).

To install and adjust a STAT-DRI plate, follow these steps:

  1. Hold a plate over the desired position, tilted slightly forward with the tabs down.
  2. Insert the tabs between the mesh of the unwrapped instrument rack.
  3. Each tab has an elongated slot. Slide the plate until the wire is at the end of each slot.
  4. Release the plate to the resting position.
  5. Prepare and load instruments for sterilization.

5.1 Cleaning the Cassette

Keeping the Statim cassette clean is good clinical practice and assists in the function of the unit. SciCan recommends that the interior surface be cleaned at least once a week. Use dishwashing soap or a mild detergent that does not contain chlorine. Scrub the inside of the cassette with a cleaning pad designed for use with Teflon™ coated surfaces. After scouring, rinse thoroughly with water to remove all traces of the detergent. Cleaning the inside of your cassette is very important if you regularly sterilize lubricated instruments. Coating the entire inside surface with STAT-DRI / STAT-DRI PLUS drying agent induces water to form an even coat on the inside surface, without beading. The water in contact with the hot cassette surfaces also evaporates much more efficiently. Spotting is minimized and instruments dry much better. STAT-DRI / STAT-DRI PLUS should be applied every 10 cycles, and after every cassette cleaning.



Stat-Dri vs. Jet-Dry

Stat-Dri Plus is specially formulated to protect stainless steel instruments. All microbiological sterilization efficacy testing has been done using Stat-Dri. We have not conducted such tests using Jet-Dry, and therefore cannot provide any data to support using any Jet-Dry products as an alternative.

Keep in mind there are several flavours of Jet-Dry on the market, including Jet-Dry with baking soda, Jet-Dry Turbo-Dry, etc. all of which have slightly different chemical composition. As a result, customers who choose to use Jet-Dry instead of Stat-Dri do so at their ‘own risk’.

Courtesy of Statim.us

 

VistaCool direct-to-drain systems

V7601
$999
Pre-order
1
Product Details
Brand: SciCan
Model: 2000, 5000, 900

Never empty your STATIM condenser bottle again!

VistaCool - the only direct-to-drain system designed from the ground up for your STATIM 2000 and 5000 cassette autoclaves. VistaCool eliminates the need for autoclave condenser bottles by cooling sterilizer wastewater and sending it directly down the drain automatically.

Protect Cabinets

Helps prevent mold, mildew, rot and rust caused by spills and humid environments created by exhaust from condenser bottles.

Protects Drains

Prevents autoclave wastewater from damaging plumbing. Built-in backflow prevention meets or exceeds local plumbing codes..

Protects Staff

Eliminates the need for office staff to empty hot water bottles manually.

Saves Time


Install Anywhere

The innovative design of the new VistaCool 3 provides all the same benefits as its predecessors, while occupying less space. The system’s included mounting clips and pressurized drain line enable it to be installed vertically or horizontally in almost any location.

  • FAST Drains STATIM exhaust safely and automatically.
  • EFFICIENT Eliminates wasted staff time emptying condenser bottle.
  • COST EFFECTIVE Dedicate more resources to patient care and less on maintenance

SciCan VistaCool Sophisticated wax motor allows cold water into the system ONLY when the sterilizer is in use.

FEATURES
UNIVERSAL SYSTEM
VistaCool will work with the STATIM 2000 or 5000 and other select sterilizers.
ROBUST
System will continuously cool your STATIM’s hot exhaust and drain it safely – no matter how many cycles you run.
VALIDATED
VistaCool is the only direct-to-drain product designed to safely and effectively drain the steam exhaust from a STATIM 2000 or 5000 and other select sterilizers.

SMART DESIGN
Triangular water tank is shaped to take up less space under your sink. Double unit services two sterilizers. No counter drilling or air gap (in most cases).

COMPLIANT
All components and system set-up are compliant with most regional plumbing codes.

COMPATIBLE
Can be used with all drainage pipe material types.
ECO DESIGN
Water tank is made of recycled plastic material.
EASY TO USE
No consumable parts and no daily maintenance is required.

Over the last 20 years, the STATIM cassette autoclave is one of the quintessential innovations in sterilization technology and enjoys leadership in the body art, dental and ophthalmology markets in over 90 countries. Designed to sterilize in a fraction of the time compared to traditional autoclaves, the STATIM reduced the quantity of expensive instruments needed.

To enhance the STATIM functionality, SciCan is proud to introduce the latest innovation to the STATIM brand: the VistaCool. The VistaCool is a direct-to-drain system whereby the STATIM is connected directly to the office or clinic plumbing. What this means is, rather than the STATIM unit draining into the external drainage bottle, the STATIM can now vent the used sterilization water directly down the main office drain.

There are many benefits of venting the STATIM unit directly down the drain, most notably saving time and increasing office efficiency. The VistaCool will save time, as a staff person will no longer be responsible for regularly emptying the bottle.

The VistaCool uses cold city water to cool the steam quickly and efficiently. The thermal sensor only activates when the system is in use, so water is only used when it’s needed. The built-in safety feature prevents the system from overheating and damaging office cabinetry.

Specifications

V7501 V7502 V7601
Tank Material Polyethylene – Gray Gray ABS Tank, PVC End Caps
Tank Dimensions 10.75" W x 5.75" L x 13.75" H 4.0" W x 13.0" L x 17.0" H 3.5" Diameter x 15.0" L
Tank Volume 1.50 Gallons / 5.70 Liters 3.00 Gallons / 11.40 Liters 0.37 Gallons / 1.40 Liters
Tank Weight (w/ water & Fittings) 15.0 lbs. / 6.8 kg 28.0 lbs. / 12.7 kg 5.0 lbs. / 2.3 kg
Coolant Water Connection Supply fittings for 1/4" O.D. feed tubing included.
Drain/Wastewater Connection Drain tee with fittings included. Not included.
Max Coolant Water Pressure 100 psi / 6.9 bar
Max Altitude (If using Air Gap) 6,561 feet / 2000 meters