HYDRIM L110W G4

SciCan_HYDRIM_G4

  • HYDRIM C and L Brochure
  • HYDRIM L Brochure
  • HYDRIM L Quick Reference Guide
  • Under counter steri-center installation, but can also be a freestanding unit

  • G4 web portal interface includes data storage, service logs and remote access capabilities

  • Validated cycles to ensure repeatable washing performance

  • Ten 8” x 11” IMS cassette capacity

  • USB port for data storage

  • Robust stainless steel exterior

    Includes pump for liquid detergent

  • Web based documentation software included – no installation required

  • Active hot air drying

  • Manufactured in Canada

hydrim-l110w-g4-side-open-2014

HYDRIM L110w G4 instrument washer

HYDRIM L110w can process 2,500 instruments in a 10-hour day HIP cleaning solution is stored in the unit, so no extra storage space requirements
Large variety of furniture options available

 

CONNECT

PROTECT

COLLECT

scican_hydrim_g4_3

The HYDRIM G4 is capable of communicating directly with service personnel or anyone you choose.

Should the HYDRIM G4 ever need attention, diagnostic information can be sent via email to pre-selected dealer service reps, significantly reducing down time.

scican_hydrim_g4_2

Patient safety relies on attention to detail. The HYDRIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle.

This encourages extra attention to process and creates a safer environment for both staff and patient.

scican_hydrim_g4_1

With each cycle, information must be stored to protect your office and your patients. The integrated data logger store all cycle information for the lifetime of the unit.

A USB port allows for the manual retrieval of cycle history. The 10/100 Base-T Ethernet connection puts your PC in direct contact with your HYDRIM G4 and the RS232 serial printer port allows you to connect with an external printer.

 

HYDRIM MEETS THE INTERNET

scican_hydrim_c61w_keyscican_g4

A high-resolution, 65K color touch screen offers a vivid display of messages, current cycle information and customizable colors all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-center, and its 2.5-inch by 3-inch dimensions allow easy viewing of cycle information.

HYDRIM L110w G4 SPECIFICATIONS

Dimensions: (w x h x d) 600 x 850 x 600 mm
(23.8” x 33.5” x 23.8”)
Depth with door open: 1200 mm / 47”
Weight: 80 kg / 176 lbs.
Cycle Times* Rinse and Hold 5 mins
Regular Wash + Dry 16 mins. + 10 mins.
Heavy Duty Wash + Dry 25 mins. + 10 mins.
Water Consumption Per Cycle:
Rinse and Hold 16 litres / 4.28 gallons
Regular Wash 24 litres / 6.34 gallons
Heavy Duty Wash 32 litres / 8.45 gallons
Electrical Connection
Electrical Rating: 208-240V, 12A, 60 Hz
Running noise: < 78 dB
Water and Drain Connections
Hot and Cold Water Tap Connection 3/4” Garden hose, male
Recommended Hot Water Temperature   60°C / 140°F
Cold Water Temperature < 30°C / 86°F
Inlet Water Pressure 1 – 10 bar / 14.5 – 145 psi
Drain 2 cm / 3/4”

Why Use A HYDRIM Automated Washer?

The advantages of automated washing systems over traditional manual cleaning are recognized by the CDC and independent research and testing organizations. If it’s not clean, it can’t be sterilized. SciCan offers the tabletop HYDRIM C51w instrument washer and the newly redesigned floor model HYDRIM L110w to meet the needs of your studio or clinic.

Key benefits to your studio or practice are:

Virtually eliminates hand scrubbing

Protect staff against the hazards of skin puncture and aerosolized contaminants from manual or ultrasonic washing, manual rinsing and manual drying.

Save valuable time

Spend less time on meticulous manual cleaning.

Third party cleaning validation indicates 99.9% protein removal

HYDRIM’S powerful circulation pumps and wash arms, combined with SciCan’s HIP chemical, result in exceptional cleaning performance.

Proprietary Chemical

HIP chemical is a proprietary blend of surfactants (Surface Acting Agents), which are substances that reduce the surface tension of the water and increase its ability to lift debris from instruments. Your valuable instruments are cleaned and protected with HIP!

Consistent repeatable cycles

Ensure that every set of instruments receives the same validated cleaning process, without the variability inherent in manual scrubbing and ultrasonic cleaners.

Fresh water and chemical for each load

A precise amount of liquid cleaning solution is dispensed automatically. In contrast with ultrasonic cleaners, HYDRIM uses fresh water for each cycle.

Easily adaptable for either loose instruments or cassettes

Accommodates your current instrument management procedures.

The HYDRIM® Washing System

Prior to placing instruments in the HYDRIM, remove gross debris. Then load instruments in cassettes or baskets, place in the HYDRIM, and press start. HYDRIM’s rapid cycles wash, rinse and dry your instruments, preparing them for sterilization in STATIM® or other autoclaves. The HIPTM chemical (HYDRIM Cleaning Solution with Instrument Protection) has been carefully formulated to provide outstanding compatibility with a wide range of materials and coatings. HIP is automatically added at various stages in the cycle to optimize the cleaning and protection of instruments. Independent testing indicates 99.9% protein removal — far beyond the level detectable with the naked eye! Speed, durability, proprietary chemical and software; these are the elements that combine to make HYDRIM the best instrument washing system available.

HYDRIM Instrument Washers — Designed for Professional Use


VistaPure deionized water treatment system

V3000
$3,399
In stock
1
Product Details
Brand: SciCan
Model: Statim, StatClave, Bravo, Hydrim C, Hydrim L


Your Steri-Center’s best friend.

VistaPure™ provides two grades of high-quality water for autoclaves, dental bottles, ultrasonic cleaners and instrument washers for the ultimate convenience.


Features

Universal System

VistaPure will work with the STATIM® Cassette Autoclaves, BRAVO™ Chamber Autoclaves, HYDRIM® Instrument Washers, Ultrasonic Cleaners, Dental Bottles, other select sterilizers and automated washers.

High Quality Water

Water is autoclave-ready, distilled quality (deionized) water which eliminates the need to buy distilled water or own a distiller.

Easy to Use

VistaPure’s handheld, point-and-shoot wand makes it easy for anyone to fill autoclaves, no matter where they’re located, and the system’s mounted faucet makes it easy to fill Dental Unit bottles over a sink. We will also offer unique “automatic water filling control” options for our STATIM and BRAVO sterilizers along with our HYDRIM final rinse options.

Smart Design

VistaPure’s filter panel fits neatly under the steri-center counter with slides for easy access to the filters.

Convenient

VistaPure provides a high volume of ready-to-use water, on demand. Its large 4.25-gallon storage tank means you don’t need to wait for deionization and R/O processes to take place.

Consistent

Each VistaPure features an in-line TDS meter that monitors water quality—and also makes it easy to know when it’s time to replace your filters.

Hands Free

VistaPure accessories include patented AutoFill devices designed to replenish SciCan STATIM and BRAVO autoclaves with distilled-quality water automatically, enabling truly hands-free convenience. An optional adapter kit is also available for utilizing VistaPure’s hyper-filtered water for the final rinse cycle of instrument washers.

Articles

VistaPure AutoFill

VistaPure’s patented AutoFill accessories replenish SciCan STATIM®and BRAVO™ autoclaves with distilled-quality water automatically — enabling truly hands-free convenience.

VistaPure AutoFill accessory kits work with all VistaPure systems and can be installed easily on any STATIM 2000/G4 or STATIM 5000/G4, or any BRAVO autoclave, in just a few minutes!

  • No more purchasing and storing distilled water
  • No more cycle-fault errors caused by forgetting to fill reservoirs
  • No more spills while filling autoclaves manually
  • No more staff time spent filling autoclaves = more time with patients

VistaPure AutoFill Installation

A 12-foot length of clear polyurethane tubing is already attached to the AutoFill manifold. If the desired distance between the connection to the VistaPure and the autoclave is greater than 12 feet, simply order a longer length of the clear polyurethane tubing, as the distance from the VistaPure to the autoclave is not limited, except by the feed tubing.

Installing AutoFill on a STATIM

The VistaPure AutoFill for STATIM device (S3020) can be installed on any STATIM 2000/G4 or STATIM 5000/G4 autoclave as follows:

https://www.scican.com/us/media/water-management/SD-491_US_EN%20R1_Autofill_Sell%20Sheet_20160805_PRNT.pdf

Installing AutoFill on a BRAVO

The VistaPure AutoFill for BRAVO device (S3030) can be installed on any model BRAVO autoclave.

In order to connect the VistaPure AutoFill to the BRAVO, one of the two tanks that come with the BRAVO must be selected as a “relay tank” since the BRAVO system uses a suction-lift pump to fill its reservoir when in its automatic-filling mode. Note that the relay tank must be located within 6 feet of the BRAVO unit, due to the suction-lift capacity of the BRAVO pump.


Connecting to a StatClave G4


Save this product for later