HYDRIM L110W G4

SciCan_HYDRIM_G4

  • HYDRIM C and L Brochure
  • HYDRIM L Brochure
  • HYDRIM L Quick Reference Guide
  • Under counter steri-center installation, but can also be a freestanding unit

  • G4 web portal interface includes data storage, service logs and remote access capabilities

  • Validated cycles to ensure repeatable washing performance

  • Ten 8” x 11” IMS cassette capacity

  • USB port for data storage

  • Robust stainless steel exterior

    Includes pump for liquid detergent

  • Web based documentation software included – no installation required

  • Active hot air drying

  • Manufactured in Canada

hydrim-l110w-g4-side-open-2014

HYDRIM L110w G4 instrument washer

HYDRIM L110w can process 2,500 instruments in a 10-hour day HIP cleaning solution is stored in the unit, so no extra storage space requirements
Large variety of furniture options available

 

CONNECT

PROTECT

COLLECT

scican_hydrim_g4_3

The HYDRIM G4 is capable of communicating directly with service personnel or anyone you choose.

Should the HYDRIM G4 ever need attention, diagnostic information can be sent via email to pre-selected dealer service reps, significantly reducing down time.

scican_hydrim_g4_2

Patient safety relies on attention to detail. The HYDRIM G4 supports verifiable processes that are PIN protected with user-defined IDs so that staff members can be required to authorize a cycle.

This encourages extra attention to process and creates a safer environment for both staff and patient.

scican_hydrim_g4_1

With each cycle, information must be stored to protect your office and your patients. The integrated data logger store all cycle information for the lifetime of the unit.

A USB port allows for the manual retrieval of cycle history. The 10/100 Base-T Ethernet connection puts your PC in direct contact with your HYDRIM G4 and the RS232 serial printer port allows you to connect with an external printer.

 

HYDRIM MEETS THE INTERNET

scican_hydrim_c61w_keyscican_g4

A high-resolution, 65K color touch screen offers a vivid display of messages, current cycle information and customizable colors all with extraordinary clarity. Fully adjustable contrast levels let you optimize the screen to the lighting in your steri-center, and its 2.5-inch by 3-inch dimensions allow easy viewing of cycle information.

HYDRIM L110w G4 SPECIFICATIONS

Dimensions: (w x h x d) 600 x 850 x 600 mm
(23.8” x 33.5” x 23.8”)
Depth with door open: 1200 mm / 47”
Weight: 80 kg / 176 lbs.
Cycle Times* Rinse and Hold 5 mins
Regular Wash + Dry 16 mins. + 10 mins.
Heavy Duty Wash + Dry 25 mins. + 10 mins.
Water Consumption Per Cycle:
Rinse and Hold 16 litres / 4.28 gallons
Regular Wash 24 litres / 6.34 gallons
Heavy Duty Wash 32 litres / 8.45 gallons
Electrical Connection
Electrical Rating: 208-240V, 12A, 60 Hz
Running noise: < 78 dB
Water and Drain Connections
Hot and Cold Water Tap Connection 3/4” Garden hose, male
Recommended Hot Water Temperature   60°C / 140°F
Cold Water Temperature < 30°C / 86°F
Inlet Water Pressure 1 – 10 bar / 14.5 – 145 psi
Drain 2 cm / 3/4”

Why Use A HYDRIM Automated Washer?

The advantages of automated washing systems over traditional manual cleaning are recognized by the CDC and independent research and testing organizations. If it’s not clean, it can’t be sterilized. SciCan offers the tabletop HYDRIM C51w instrument washer and the newly redesigned floor model HYDRIM L110w to meet the needs of your studio or clinic.

Key benefits to your studio or practice are:

Virtually eliminates hand scrubbing

Protect staff against the hazards of skin puncture and aerosolized contaminants from manual or ultrasonic washing, manual rinsing and manual drying.

Save valuable time

Spend less time on meticulous manual cleaning.

Third party cleaning validation indicates 99.9% protein removal

HYDRIM’S powerful circulation pumps and wash arms, combined with SciCan’s HIP chemical, result in exceptional cleaning performance.

Proprietary Chemical

HIP chemical is a proprietary blend of surfactants (Surface Acting Agents), which are substances that reduce the surface tension of the water and increase its ability to lift debris from instruments. Your valuable instruments are cleaned and protected with HIP!

Consistent repeatable cycles

Ensure that every set of instruments receives the same validated cleaning process, without the variability inherent in manual scrubbing and ultrasonic cleaners.

Fresh water and chemical for each load

A precise amount of liquid cleaning solution is dispensed automatically. In contrast with ultrasonic cleaners, HYDRIM uses fresh water for each cycle.

Easily adaptable for either loose instruments or cassettes

Accommodates your current instrument management procedures.

The HYDRIM® Washing System

Prior to placing instruments in the HYDRIM, remove gross debris. Then load instruments in cassettes or baskets, place in the HYDRIM, and press start. HYDRIM’s rapid cycles wash, rinse and dry your instruments, preparing them for sterilization in STATIM® or other autoclaves. The HIPTM chemical (HYDRIM Cleaning Solution with Instrument Protection) has been carefully formulated to provide outstanding compatibility with a wide range of materials and coatings. HIP is automatically added at various stages in the cycle to optimize the cleaning and protection of instruments. Independent testing indicates 99.9% protein removal — far beyond the level detectable with the naked eye! Speed, durability, proprietary chemical and software; these are the elements that combine to make HYDRIM the best instrument washing system available.

HYDRIM Instrument Washers — Designed for Professional Use


Statim 2000 G4

G4-121101
$6,490
Latest revision STATIM 2000 G4 for Piercers with new touchscreen, PC board, and probe bracket with recessed thermocouple
In stock
1
Product Details
Brand: SciCan
Model: 2000 G4

Fast, Gentle, Reliable, and Smart.

Introducing The New Generation of Statim, The Statim G4 Series

(Generation Four)

Download brochure

Canonsburg, PA – SciCan has set the benchmark for sterilization and instrument reprocessing technology.

For more than 25 years SciCan has been developing and manufacturing highly innovative infection control products that address the need for versatility, flexibility, and efficiency in today’s environments.

SciCan is proud to unveil the newest STATIM family member, the G4 series. The STATIM G4 series is the same renowned and trusted autoclave it has been for over 25 years but now boasts a new contemporary look, functionality and connectivity that is the first of its kind. The G4 technology will change the way you interact by providing a direct channel of communication through the Internet to increase productivity and limit downtime.

Still powered by SciCan’s signature steam technology to provide sterilization at speeds faster than conventional chambered autoclaves, the STATIM G4 series has been drastically upgraded with a level of interactivity not seen before.

New look

The STATIM G4 series has been modernized with a new fascia that is fresh and contemporary.

Color touch screen

A large 3.5” high-resolution touchscreen offers a vivid display of messages and current cycle information all with extraordinary clarity. The bubble level has been integrated into the high-resolution touchscreen.

Built-in data logger

Gone are the days of messy thermal paper, clumsy printers or potential failures with external data loggers. With increasing stringency amongst national guidelines, the STATIM G4 series now saves all the data from each cycle. This data can be copied onto the included USB drive, viewed on screen, or remotely stored in the Cloud via email.*

STATIM G4 technology

SciCan's STATIM G4 series Technology offers a platform with endless possibilities. The product expansion and modes of communication will provide visibility from every facet, from usability to troubleshooting.

This is a very exciting time for SciCan, as we are embarking into new territory with cutting edge technology. SciCan has always demonstrated innovation and this is just another example of how we are setting new standards for infection control.

*Based on your email providers storage capabilities


This model has all the benefits of our classic STATIM 2000 Cassette Autoclave

  • Ultra-fast 6 minute unwrapped cycle
  • 14 minute wrapped cycle
  • Exceptional instrument turnover
  • 10 minute Dri-Tecc Drying Technology
  • Aseptic transfer of instrument directly to the point-of-use
  • Reduced instrument investment
  • Prolongs instrument life

Like the STATIM 900, the STATIM 2000 boasts a 6-minute cycle, but has the added advantage of employing a fully removable chamber so you can aseptically transport a set of freshly sterilized instruments directly to the procedure area.

The STATIM 2000 is fully automatic. Simply select one of the three sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's STATIM cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States, and Europe.

The STATIM 2000 is a reliable cassette sterilizer that's compact enough to fit in procedure areas and fast enough to sterilize jewelry, expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just six minutes and a wrapped cycle in 14 minutes.

Dri-TecC – Convection heat drying technology

The STATIM 2000 uses convection heat to dry instruments by utilizing the remaining heat in the system after the sterilization phase. Heat is captured and released into the cassette, drying wrapped instrument loads in as little as 10 minutes.

Sterilization cycle description chart

Cycle Unwrapped Wrapped Rubber/Plastic
Sterilization time 3.5 minutes 10 minutes 15 minutes
Sterilization temp. 135º C 135º C 121º C
Total cycle time 6 minutes 14 minutes 20 minutes


ACCESSORIES available in the Shop
: see below

01-100008A Cassette complete (includes 01-106653 Instrument rack for wrapped instruments)

01-100028S Seal & lubricant kit

01-100207S Air compressor filter

01-102119S Microbiological air filter

01-100812S Waste bottle complete (includes 01-100204S Exhaust tube)

SCI134 Test Strip indicators (box of 250)

SCI-T5 Sterilization Monitor Type 5 Chemical Indicator

01-101783S Water reservoir cap & filter (Includes 01-109300S Water reservoir filter)

SPECIFICATIONS:

Unit Size : L 480mm x W 415mm x H 150mm
L 19" x W 16.25" x H 6"
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11" x W 7" x H 1.5"
Reservoir Capacity : 4.0 litres (distilled water) Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 1300 W

When you receive your Statim 2000 packing carton, the items listed below will be included.
If any of the items are missing, contact us immediately so that the situation can be corrected.

  • Cassette Tray and Lid
  • Instrument Rack
  • Waste Bottle
  • Bottle Lid Fitting
  • Exhaust Tube
  • Tube Mounting Hardware
  • Power Cord
  • Operator's Manual

STATIM G4 Cassette Autoclave In-service (United States)