General StatIM Preventative Maintenance:

To ensure trouble-free performance, both the operator and the dealer must follow a preventative maintenance schedule.

NOTE: Please refer to your National, Regional, State or Safety laws for any additional reoccurring user testing that may be required.

OperatorPreventative maintenance actionPart

Daily

Water Reservoir💧Replace water as needed. (Use distilled water <5ppm TDS)
💧Empty the waste bottle every time you refill the water reservoir.
💧For ophthalmic use, drain at the end of every workday, leave empty, and refill at the start of the next workday.
Water distiller
VistaPure
TDS Meter
Waste Bottle💧Empty the waste bottle every time you refill the water reservoir.
💧Fill the bottle with water, up to the MIN line marking.
Waste bottle and parts

Weekly

Cassette💧Wash the interior of the cassette with dishwashing soap or a mild detergent that does not contain chlorine.
💧Scrub the inside with a cleaning pad designed for use with Teflon™-coated surfaces.

💧After removing all traces of the detergent, treat interior surfaces of the cassette with the STAT-DRI™Plus drying agent to enhance the drying process.

Cassette
STAT-DRI™ Plus
Biological and/or Air Filter🔎Check the filter for dirt and moisture.
🔁Replace if dirty. ⚠️Call for service if wet.💧
Biological Filter
Air Filter
Water Filter🔎 Check the water reservoir filter every week and clean if necessary. Replace only if necessary.Reservoir filter

Every 6 months

Cassette Seal🔁Replace every 500 cycles or six months (whichever is first), or whenever necessary.
🔎Video: How to change the cassette seal
Cassette seal
Biological and/or Air Filter🔁 Replace every 500 cycles or six months (whichever is first).Maintenance Kit:
Cassette seal and both air filters
Regular preventative maintenance

TechnicianOnce a yearPart
Cassette🔎Check the tray, lid and seal for damage. Replace if necessary.
Biological Filter🔎Inspect the biological filter for moisture.
Solenoid Valve🔎Inspect the valve and clean if dirty. Replace the plunger if defective.
Pump🔎Replace in-line water filter.
Check Valve🔎Remove the exhaust tube from the back of the unit during the air drying phase. 🔎Check for air coming from the fitting.

 🔎Remove the air compressor tube from the check valve inlet while running a cycle. Make sure no steam is leaking from the valve. Replace if there are any leaks

Water Reservoir🔎Check the reservoir for dirt. Clean and rinse with steam process distilled water if necessary.
Calibration🔎Calibrate the unit.
Annual preventative maintenance

 

More information about preventative maintenance subscriptions

Here is the free poster and links to individual parts to keep on hand to keep things working smoothly:

Consider also a second sterilization cassette: STATIM 2000 Sterilization Cassette [parts available separately]

Also, to protect the cover of your Statim: STATMAT protective cover for STATIM 2000 + G4


More details:

reservoir_cap_filter

Water Reservoir

Replace water as needed with pure distilled water (Less than 5 parts per million of Total Dissolved Solids)

For ophthalmic use, drain at the end of every workday, leave empty, and refill at the start of the next workday.

Statim reservoir view of exit hole, float and water quality sensor

🔎Statim reservoir view of exit hole, float and water quality sensor

Waste Bottle complete with tubing is included with the STATIM sterilizer

Waste Bottle

Empty the waste bottle every time you refill the water reservoir.

Fill the bottle with water, up to the MIN line marking.

Get a new waste bottle or parts, such as tubing or the top fixture.

cassette_volumes

Cassette

Wash the interior of the cassette with dishwashing soap or a mild detergent that does not contain chlorine.

Scrub the inside with a cleaning pad designed for use with Teflon®-coated surfaces.

STAT-DRI Plus dramatically shortens drying time in your autoclave!

STAT-DRI Plus dramatically shortens drying time in your autoclave!

STAT-DRI Plus refills can be ordered in our shop

Water Reservoir Filter and Cap Kit

STATIM Water Reservoir Filter and Cap Kit

Check the water reservoir filter every week and clean if necessary.

Replace Filter only if necessary.

IMPORTANT UPGRADE: Get a new cap and water filter kit if your STATIM does not have one.

Replacing the water reservoir filter: read full article

Air and Biological Air Filters for STATIM 2000 (shown)

Biological Filter

Air and Biological Air Filters for STATIM 2000 (compressor shown open)

Replace both air filters every 500 cycles or six months (whichever is first).

Get a new biological filter. Older units will not have the biological air filter.

⚠️ Call for service if wet. The check valve will need to be replaced.

This biological filter is wet. 

The check valve must be replaced

⚠️This biological filter is wet.
The check valve must be replaced

Replace your STATIM air filters every six months or else it will look like the gross dirty yellow one top left! (STATIM 2000 air compressor filter shown)

Air Filter

Replace both your STATIM air filters every six months or else it will look like the dirty yellow one top left!
(STATIM 2000 air compressor filter shown)

Replace every 500 cycles or six months (whichever is first). Get a new air filter.

Seal & Lube Kits

STATIM Cassette Seal & Lube Kits

[Seals go green! Read full article]

Replace every 500 cycles or six months (whichever is first), or whenever necessary. Get a new cassette seal.

If you need further assistance, a STATIM user’s manual, Reference Poster, or a Troubleshooting Guide, please contact us

Brian Skellie and our team will help!

VistaCool direct-to-drain systems

V7601
$999
Pre-order
1
Product Details
Brand: SciCan
Model: 2000, 5000, 900

Never empty your STATIM condenser bottle again!

VistaCool - the only direct-to-drain system designed from the ground up for your STATIM 2000 and 5000 cassette autoclaves. VistaCool eliminates the need for autoclave condenser bottles by cooling sterilizer wastewater and sending it directly down the drain automatically.

Protect Cabinets

Helps prevent mold, mildew, rot and rust caused by spills and humid environments created by exhaust from condenser bottles.

Protects Drains

Prevents autoclave wastewater from damaging plumbing. Built-in backflow prevention meets or exceeds local plumbing codes..

Protects Staff

Eliminates the need for office staff to empty hot water bottles manually.

Saves Time


Install Anywhere

The innovative design of the new VistaCool 3 provides all the same benefits as its predecessors, while occupying less space. The system’s included mounting clips and pressurized drain line enable it to be installed vertically or horizontally in almost any location.

  • FAST Drains STATIM exhaust safely and automatically.
  • EFFICIENT Eliminates wasted staff time emptying condenser bottle.
  • COST EFFECTIVE Dedicate more resources to patient care and less on maintenance

SciCan VistaCool Sophisticated wax motor allows cold water into the system ONLY when the sterilizer is in use.

FEATURES
UNIVERSAL SYSTEM
VistaCool will work with the STATIM 2000 or 5000 and other select sterilizers.
ROBUST
System will continuously cool your STATIM’s hot exhaust and drain it safely – no matter how many cycles you run.
VALIDATED
VistaCool is the only direct-to-drain product designed to safely and effectively drain the steam exhaust from a STATIM 2000 or 5000 and other select sterilizers.

SMART DESIGN
Triangular water tank is shaped to take up less space under your sink. Double unit services two sterilizers. No counter drilling or air gap (in most cases).

COMPLIANT
All components and system set-up are compliant with most regional plumbing codes.

COMPATIBLE
Can be used with all drainage pipe material types.
ECO DESIGN
Water tank is made of recycled plastic material.
EASY TO USE
No consumable parts and no daily maintenance is required.

Over the last 20 years, the STATIM cassette autoclave is one of the quintessential innovations in sterilization technology and enjoys leadership in the body art, dental and ophthalmology markets in over 90 countries. Designed to sterilize in a fraction of the time compared to traditional autoclaves, the STATIM reduced the quantity of expensive instruments needed.

To enhance the STATIM functionality, SciCan is proud to introduce the latest innovation to the STATIM brand: the VistaCool. The VistaCool is a direct-to-drain system whereby the STATIM is connected directly to the office or clinic plumbing. What this means is, rather than the STATIM unit draining into the external drainage bottle, the STATIM can now vent the used sterilization water directly down the main office drain.

There are many benefits of venting the STATIM unit directly down the drain, most notably saving time and increasing office efficiency. The VistaCool will save time, as a staff person will no longer be responsible for regularly emptying the bottle.

The VistaCool uses cold city water to cool the steam quickly and efficiently. The thermal sensor only activates when the system is in use, so water is only used when it’s needed. The built-in safety feature prevents the system from overheating and damaging office cabinetry.

Specifications

V7501 V7502 V7601
Tank Material Polyethylene – Gray Gray ABS Tank, PVC End Caps
Tank Dimensions 10.75" W x 5.75" L x 13.75" H 4.0" W x 13.0" L x 17.0" H 3.5" Diameter x 15.0" L
Tank Volume 1.50 Gallons / 5.70 Liters 3.00 Gallons / 11.40 Liters 0.37 Gallons / 1.40 Liters
Tank Weight (w/ water & Fittings) 15.0 lbs. / 6.8 kg 28.0 lbs. / 12.7 kg 5.0 lbs. / 2.3 kg
Coolant Water Connection Supply fittings for 1/4" O.D. feed tubing included.
Drain/Wastewater Connection Drain tee with fittings included. Not included.
Max Coolant Water Pressure 100 psi / 6.9 bar
Max Altitude (If using Air Gap) 6,561 feet / 2000 meters

Download

Brochure

Save this product for later