OPTIM 33TB cleaning protocol

SciCan_OPTIM_USA

OPTIM™33 TB Quick Reference Guide

SWITCHING TO OPTIM 33 TB

Give all surfaces a rinse with mild soap & water before switching to OPTIM.

SciCan_OPTIM_USAQUATs (Quaternary Ammonium Compounds) or phenol based disinfectants are common active ingredients in the dental operatory today and are known to leave residual active chemistry on surfaces. AHP (Accelerated Hydrogen Peroxide) is an oxidizer and will remove chemical residues left by other surface disinfectants. There may be odor or film development if surfaces are not rinsed (damp wiped) properly with soap & water. This odor or film should however dissipate on average within 7 to 10 days of continual use as AHP will remove the residual active ingredient.

Surfaces need to be periodically rinsed with water!

Dissents or complaints happen when users are not informed on the correct protocol when using the product. It is good practice to periodically (at least once a week) rinse or wipe surfaces with a damp cloth to remove surfactants (detergents) or residual active ingredients that can build up over time with the use of ANY disinfectant cleaner.

No mixing of chemistries!

Mixing of chemistries in operatory i.e. using quats-alcohol/phenol disinfectant and OPTIM 33 TB in the same operatory or refilling OPTIM into chemical container used previously for other chemicals is not recommended. It is best practice to never mix chemistries (any kind) no matter what industry you are in.

On which surfaces can OPTIM 33 TB be used?

Non-porous hand contact environmental surfaces including Naugahyde (vinyl coated upholstery fabric).

NOTE: Soft surfaces such as chairs and cables should be periodically rinsed with water or wiped with a damp cloth to prevent the build-up of disinfectant or surfactants. As best practice, for any kind of disinfectant or cleaners used, chairs should be wiped with a damp cloth at the end of the day or at least once a week.

PRECAUTIONS:

– Surfaces that are composed of brass or copper, or other ferrous metals may show signs of discoloration or pitting with prolonged exposure.

– Anodized aluminum (often used on hand-pieces) and carbon tipped instruments should be avoided (i.e. burrs). Material impact can be reduced with rinsing or damp wiping.

We advise against wrapping gauze pad or ‘sleeves’ soaked in disinfectant on hand-pieces.


OPTIM 33 TB Solution

OPTIM 33TBSpray – Wipe – Spray Protocol

Visibly Soiled Surface – Clean before disinfecting

  1. Spray OPTIM 33 TB directly onto surface.
  2. Wipe visible soil with Stat-Wipes or clean paper towel to clean surface.
  3. Discard soiled towelette.
  4. Continue to disinfection step

Visibly Clean Surface – Disinfect pre-clean surface

  1. Spray OPTIM 33TB to cover the pre-clean surface. Allow the disinfectant to remain
  2. undisturbed on the surface for the contact time indicated on the label.
  3. *Do not overspray as this can create pooling of liquid. OPTIM 33TB is water based not alcohol based.
  4. Wipe with Stat-Wipes or clean paper towel.
  5. Discard used towelette.

*Using gauze dipped in solutions for wiping can cause pooling of liquid on surface. Wipe surface dry with paper towel if surface is still wet after desired contact time is achieved.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One- Step Cleaner Disinfectant. Therefore, OPTIM can be used on visibly clean surface. Depending on the soil load on the surface, the 2 step process is not required due to this EPA claim.


OPTIM 33 TB Wipes

Standard Protocol for Visibly Soiled Surface

Clean before disinfecting

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Clean surface with towelette to remove organic matter or visible blood.
  3. Discard used towellete.

Disinfect After Cleaning

  1. Pull out OPTIM 33 TB towelette from the canister.
  2. Disinfect surface with towelette.
  3. Allow surface to remain wet for the recommended contact time.
  4. Discard used towelette.

** OPTIM 33 TB has been tested in accordance with EPA organic soil load requirement as a One-Step Cleaner Disinfectant. Depending on the soil load on the surface, users have the choice of cleaning the surface with one side of the wipe and disinfecting the surface with the reverse side of the wipes. Always allow surface to remain wet for the recommended contact time.

Because OPTIM 33 TB is approved as a One-Step Cleaner Disinfectant, depending on the soil load, the 2 step process may not be required due to this EPA claim.

Get Optim in our Store

Refill Dry Wipes (18/case) (Can not included)

SCI33R18
$232
Would you like to buy this product one time or subscribe for it?
In stock
1
Product Details
Brand: SciCan
Model: Optim

STAT-Wipes work well with OptIM disinfectant cleaner

Save with Stat-wipes

Premium Quality dry towelette refills

STAT-Wipes allow you to make your own disinfection wipes by adding the surface disinfectant of your choice such as OPTIM 33TB to our premium dry towelettes.

*Please note that OPTIM 1 or OPTIM 33TB chemical has to be ordered separately

STAT-Wipes are an easy-to-use and environmentally responsible solution for your surface disinfection needs.

Get OPTIM

PREMIUM QUALITY

The wipes feature a special superior quality design. The unique, non-woven bond pattern with uniform pore size ensures that the liquid is present on the substrate rather than being absorbed.

The result:
  • The liquid is deposited onto the surface instead of staying inside the wipe
  • Wipes remain thoroughly wet and do not dry out
  • Durable and strong with no lint residue
  • Capable of covering a large area with minimal wipe use
  • Economical consumption with less waste
  • Please note: Empty cans no longer sold separately

Instructions, when using with OPTIM 33TB:

  1. Remove lid and fill container with 25 oz. (about 3 cups) of Optim 1 or Optim 33TB surface disinfectant.
  2. Pull up corner of first wipe from center of roll and push 1/2” to 3/4” through X in lid.
  3. Replace lid.
  4. Lift lid top and pull up wipes one at a time.

When used with surface disinfectants other than OPTIM 1 or Optim 33TB, we recommend that the customer contact the chemical manufacturer to obtain more information on proper usage.

To prevent excess waste, simply reuse the STAT-Wipes container. Just insert a new roll of dry wipes and add 25 oz. of surface disinfectant. It's that easy.


* Please note that chemical has to be ordered separately. To order OPTIM 33TB or Optim 1

OPTIM 1 and OPTIM 33 TB are One-Step Disinfectant Cleaners that offer the optimal infection control choice that helps you maintain a clean and safer working environment.

Save this product for later

1 thought on “OPTIM 33TB cleaning protocol”

Leave a Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.