all-in-ONE easy-Foam-it-C3

all-in-ONE instrument cleaner

Statim 2000 G4

SKU G4-121101
$5,870
In stock
1
Product Details

Fast, Gentle, Reliable, and Smart.

Introducing The New Generation of Statim, The Statim G4 Series

Download brochure

Canonsburg, PA – SciCan has set the benchmark for sterilization and instrument reprocessing technology.

For more than 20 years SciCan has been developing and manufacturing highly innovative infection control products that address the need for versatility, flexibility, and efficiency in today’s environments.

SciCan is proud to unveil the newest STATIM family member, the G4 series. The STATIM G4 series is the same renowned and trusted autoclave it has been for over 20 years but now boasts a new contemporary look, functionality and connectivity that is the first of its kind. The G4 technology will change the way you interact by providing a direct channel of communication through the Internet to increase productivity and limit downtime.

Still powered by SciCan’s signature steam technology to provide sterilization at speeds faster than conventional chambered autoclaves, the STATIM G4 series has been drastically upgraded with a level of interactivity not seen before.

New look

The STATIM G4 series has been modernized with a new fascia that is fresh and contemporary.

Color touch screen

A large 3.5” high-resolution touchscreen offers a vivid display of messages and current cycle information all with extraordinary clarity. The bubble level has been integrated into the high-resolution touchscreen.

Built-in data logger

Gone are the days of messy thermal paper, clumsy printers or potential failures with external data loggers. With increasing stringency amongst national guidelines, the STATIM G4 series now saves all the data from each cycle. This data can be copied onto the included USB drive, viewed on screen, or remotely stored in the Cloud via email.*

STATIM G4 technology

SciCan's STATIM G4 series Technology offers a platform with endless possibilities. The product expansion and modes of communication will provide visibility from every facet, from usability to troubleshooting.

This is a very exciting time for SciCan, as we are embarking into new territory with cutting edge technology. SciCan has always demonstrated innovation and this is just another example of how we are setting new standards for infection control.

*Based on your email providers storage capabilities


This model has all the benefits of our classic STATIM 2000 Cassette Autoclave

FREE shipping

  • Ultra-fast 6 minute unwrapped cycle
  • 14 minute wrapped cycle
  • Exceptional instrument turnover
  • 10 minute Dri-Tecc Drying Technology
  • Aseptic transfer of instrument directly to the point-of-use
  • Reduced instrument investment
  • Prolongs instrument life

Promotions available:

Like the STATIM 900, the STATIM 2000 boasts a 6-minute cycle, but has the added advantage of employing a fully removable chamber so you can aseptically transport a set of freshly sterilized instruments directly to the procedure area.

The STATIM 2000 is fully automatic. Simply select one of the three sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish.

SciCan's STATIM cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States, and Europe.

The STATIM 2000 is a reliable cassette sterilizer that's compact enough to fit in procedure areas and fast enough to sterilize jewelry, expensive Lasik, PRK, endoscopic and cataract instruments, including phaco handpieces, between procedures - it can complete an unwrapped sterilization cycle in just six minutes and a wrapped cycle in 14 minutes.

Dri-TecC – Convection heat drying technology

The STATIM 2000 uses convection heat to dry instruments by utilizing the remaining heat in the system after the sterilization phase. Heat is captured and released into the cassette, drying wrapped instrument loads in as little as 10 minutes.

Sterilization cycle description chart

Cycle Unwrapped Wrapped Rubber/Plastic
Sterilization time 3.5 minutes 10 minutes 15 minutes
Sterilization temp. 135º C 135º C 121º C
Total cycle time 6 minutes 14 minutes 20 minutes


ACCESSORIES available in the Shop
:

01-100008A Cassette complete (with rack 01-106653)
01-100028S Seal & lubricant kit
01-100207S Air compressor filter
01-102119S Microbiological air filter
01-100812S Waste bottle complete
01-100204S Exhaust tube
01-103945S Instrument rack for unwrapped instruments
01-106653 Instrument rack for wrapped instruments
SCI134 Test Strip indicators (box of 250)
01-101783S Water reservoir cap & filter
01-109300S Water reservoir filter

SPECIFICATIONS:

Unit Size : L 480mm x W 415mm x H 150mm
L 19" x W 16.25" x H 6"
Cassette Internal Dimensions : L 280mm x W 180mm x H 35mm
L 11" x W 7" x H 1.5"
Reservoir Capacity : 4.0 litres (distilled water) Approximately 40 cycles
Weight without water : 21 kg/46 lbs
Power Consumption : 110-120 V, 60Hz, 1300 W

When you receive your Statim 2000 packing carton, the items listed below will be included.
If any of the items are missing, contact us immediately so that the situation can be corrected.

  • Cassette Tray and Lid
  • Unwrapped Instrument Rack
  • Waste Bottle
  • Bottle Lid Fitting
  • Power Cord
  • Operator's Manual
  • Exhaust Tube
  • Tube Mounting Hardware

*The use of STATIM sterilizers was introduced to the body art field in the early 1990's by Brian Skellie at Piercing Experience, and developed in community along with other practical innovations in applied safety precautions and techniques.

Save this product for later

Clean your instruments effectively with the all-in-ONE Universal Processing Solution

The UPS1 Enzymatic Surgical Instrument Detergents cut costs.

The Surgical Instrument Detergent Enzyme Lubricants clean residue free.

Four Enzyme Surgical Instrument Cleaning Detergent Lubricants clean faster.

This product delivers advanced enzyme surgical instrument cleaning detergent plus lubricants:

  • Enzyme Cleaners (protease, amylase, carbohydrase, and lipase)
  • Detergent Cleaners (surfactant cleaners)
  • Lubricants (water soluble and free rinsing)
  • Surface Conditioners ( strengthen the chromium passive layer of stainless steel)

Designed for use as:

  • manual surgical instrument and scope cleaning solution,
  • ultrasonic surgical instrument and scope cleaning solution,
  • automated surgical instrument washer and washer disinfector concentrate.

The Universal Processing Solution1

The Neutral pH (7) Surgical Instrument Enzymatic Detergent Lubricants clean fast and residue free. The all-in-ONE™ Surgical Instrument Cleaners deliver the four enzymes that are necessary to break down all forms of proteinaceous bioburden and the surfactant detergents to clean the surface. The all-in-ONE is highly concentrated for faster cleaning and lower cleaning costs.

The all-in-ONE Detergents deliver an average concentration that is 400% higher than the other enzyme detergents. One gallon can deliver 512 gallons (1938 liters) of cleaning and conditioning power. The dilution rate is .25 to .5 ounces per gallon (1.9 ml liters to 3.8 ml per liter) depending on the level of bioburden, encrustation, and stains.

The easy FOAM-it™ Surgical Instrument Pre wash Cleaner delivers a thick layer of long lasting foam cleaners and conditioners to speed the cleaning process. The easy FOAM-it Pre Wash and Cleaner rapidly breaks down all form of proteinaceous bioburden, cleans the surface and then rinses clean, rendering a residue free surface. When water is added or the instrument is placed into a wash basin, the foam dissipates to present a clear working surface, and NO OTHER cleaning products are needed. The easy-FOAM-it is highly concentrated to deliver all you need in ONE application.

The easy FOAM-it can replace:

all-in-ONE easy-Foam-it-C3

  • enzyme cleaners,
  • surgical instrument cleaning detergents,
  • STAIN removers,
  • surface conditioners, and
  • surgical instrument lubricants,

in one application.

Four enzymes are necessary to breakdown bioburden on soiled surgical instruments. Surgical instrument cleaners that do not contain these four enzymes cannot remove all forms of proteinaceous bioburden.

For the surgical instrument cleaning process to be thorough, four enzymes are needed:

  1. Lipase Surgical Instrument Cleaner Enzymes: for fat
  2. Amylase Surgical Instrument Cleaner Enzymes: for starch
  3. Carbohydrase Surgical Instrument Cleaner Enzymes: for high starches
  4. Protease Surgical Instrument Cleaner Enzymes: for blood

The ONLY other product that delivers these 4 enzymes is RUHOF within their higher tier products.

  • The all-in-ONE™ Cleaners and Conditioners deliver a unique formulation of detergents and multi-tiered “high-level” enzymes (Protease, Amylase, Lipase, and Carbohydrase) within a Neutral pH surfactant chemical complex.
  • The all-in-ONE™ rapidly breaks down and removes all forms of proteinaceous bioburden, cleans and conditions the surface, enhances the “passive layer” protection of surgical stainless steel, lubricates moving parts, and then rinses clean.
  • The highly concentrated all-in-ONE™ cleaners are aggressive against your most difficult cleaning challenge and guaranteed to be safe for all types of metal, rigid and flexible scopes, lenses, microsurgical instrumentation and reprocessing equipment.

 

The easy FOAM-it™ lays down a thick blanket to hydrate and remove proteinaceous debris, hard water deposits, and encrusted stains, for fast acting enzyme detergent cleaning action. When water is added the ‘foam’ dissipates to provide a clear ‘free-rinsing’ cleaning and conditioning solution.

all-in-ONE™ Surgical Instrument Cleaners and Conditioners

  • ONE product for cleaning and conditioning Surgical Instruments.
  • ONE application to thoroughly clean and condition Surgical Instruments.
  • Apply it ONCE…
  • It’s all you really need for cleaning and conditioning Surgical Instruments and Scopes as well as Tattoo, Piercing, and Body Modification equipment.

Replace Cleaning and Conditioning products for:

  • removing all forms of bioburden,
  • pre-cleaning and soaking to remove stains,
  • manual cleaning,
  • Ultrasonic cleaning, and
  • Washer Decontaminator Disinfector reprocessing.

Your cleaner instruments will look newer and perform longer.

UPS all-in-ONE™ Surgical Instrument Cleaning and Conditioning liquid available now as:

  • easy FOAM-it™ 32 ounce applicator bottle [12 bottles per case]
  • gallons [4 per case]
  • 5 gallon dispenser container
  • 15 gallon dispenser container
  • 30 gallon dispenser container
  • 55 gallon drum

Directions For Use:

Soak:

Add 1/4 to 1/2 fl.oz. of UPS1 to one gallon of diluent. Mix well. Optimal temp. range is 120°F-140°F. Completely immerse instruments in solution for 2-4 min. or more as needed for heavily soiled instruments.

Manual Cleaning:

Add 1/4 to 1/2 fl.oz. of UPS1 to one gallon of diluent. Mix well. Optimal temp. range is 120°F-140°F. Follow established cleaning protocol. Rinse thoroughly.

Automated Washer and Ultrasonic Cleaning:

Use 1/4 to 1/2 fl.oz. of UPS1 to one gallon of diluent depending on bioburden load and water hardness. Optimal temperatures: cold water pre-wash < 122°F (50°C), detergent wash 158°F (70°C) to 185°F (85°C), and final rinsing with lubrication of ~ 203°F (95°C).

MSDS